2. WIRING
2.2.2
Connector box for hull unit cable
Fasten the connector box on the side of the hull unit opposite the cable clamp [B]. Its
purpose is to act as relay for the cable which sends control signals from the transducer
unit to the hull unit. Be sure to run the thinner cable to the direction opposite to the
raise/lower drive assy as shown in the figure below.
Drive unit
1. Unfasten two hex bolts from the hull unit and use them to fasten the connector box
fixture to the hull unit.
2. Fasten connector box to the connector box fixture with two screws.
3. Connect connector MLP-15 from the drive section to the connector ELR-15 (or
MLR-15) at the end of the S10-15-5 (or S10-15-10) from the transducer unit. Set
the cable in the connector box.
4. Fasten the lid of the connector box with four screws so that lid pinches the armor
of the cable.
Remember to insert the rubber gasket.
2-4
S-10-15-5/10
Hull unit, connector box
Connector
box fixture
Hex bolt
(Unfasten two bolts
from hull unit and use them.)
Pinch the armor.
Rubber gasket
Screw
Screw for
(M4×10)
connector
box