ELECTRICAL CONNECTION

The appliance is fitted with an approved 15 Amp flexible cord and plug which must be connected to a
correctly earthed socket outlet. The manufacturer is not liable for any direct or indirect damage caused by
faulty installation or connection. It is therefore necessary that all installation and connection operations are
carried out by qualified personnel complying with the local and general regulations in force.
The wire section on the cable must not be less
2
Than1.5mm (3 × 1.5cable).Use only the special
cables available at our service centers.
CONNECTION OF THE FEEDING CABLE TO THE MAINS
Connect the feeding cable to a plug suitable for the load indicated on the rating plate of the product. In case of
a direct connection to the mains (cable without plug), it is necessary to insert a suitable omnipolar switch
before the appliance, with minimum opening between contacts of 3 mm (the grounding wire should not be
interrupted by the switch).
Before connecting to the mains, make sure that:
The electrical counter, the safety valve, the feeding line and the socket are ade
quate towithstand the maximum load required(see rating plate).
The supply system is regularly grounded, according to the regulations in force.
The socket or the omnipolar switch can easily be reached after the installation
of the oven.
After carrying out the connection to the mains, check that the supplying cable
does not come into contact with parts subject to heating.
Never use reductions, shunts, adaptors which can cause overheating or burning.
The manufacturer is not liable for any direct or indirect damage caused by faulty installation or connection. It
is therefore necessary that all installation and connection operations are carried out by qualified personnel
complying with the local and general regulations in force.
Electrical features
Oven light
Spit motor
Upper heating element
Bottom heating element
Grill heating element
Circular heating element
Ventilator motor
Cooling fan
VENTILATION AND GAS CONNECTION
Refer to AS5601, in general the appliance should have adequate ventilation for complete combustion of gas, proper flueing
and to maintain temperature of immediate surroundings within safe limits.

ADAPTATION TO DIFFERENT TYPES OF GAS

The appliance is factory set for Natural gas. The test point pressure should be adjusted to
50% of the burners operating at maximum.
The appliance is set up to operate with the gas specified on the gas type label placed on the back of the
appliance.
To perform these operations the qualified installer will follow the indications given in the "Adaptation to the
various types of gas" section. For safer operation make sure that the supply pressure respects the values given
in the "Table of burner and injector characteristics".
If installing for use with
gas cylinder supply and the test point pressure is 2.75 kPa
LPG
, ensure a gas regulator suitable for a supply pressure of
2 ×
W
25
4W
2200W
1800W
2900W
2 × 1600W
2 × 30W
11W
.
6
L
N
1.0 kPa
with
2.75 kPa
is part of the