Venini VU90EG User Manual page 6

90cm freestanding cooker
Table of Contents

Advertisement

Instructions for Installation
This appliance is suitable for connection with rigid pipe or flexible hose. The isolating manual shut-off valve connection
point must be accessible when the appliance is installed. Gas inlet is located at the top rear, right OR left hand side, 50mm
from the side edge. Overall dimensions 900mm wide, 600mm deep and 900mm high.
Natural Gas: the supplied regulator must be fitted to the appliance inlet connection. Gas pressure must be adjusted to
1.0 kPa when approximately 50% of the burners are on high flame, the appliance test point is located on the regulator.
LPG: the supplied test point adaptor must be fitted to the appliance inlet connection. Gas pressure must be adjusted to
2.75 kPa, the appliance test point is located on the test point adaptor.
Suitable for connection with a flexible hose assembly. The flexible hose assembly must be certified to AS/NZS 1869
class B or D, be of appropriate internal diameter for the total gas consumption, be kept as short as possible
(not exceeding 1200mm), must not be in contact with the floor or any hot or sharp surfaces. The hose assembly must not
be subject to strain, abrasion, kinking or deformation.
Anti tilt chains are located at the rear of the appliance and must be secured to the wall behind the appliance to prevent
accidental tipping/tilting. The chain length must be as short as practicable to avoid appliance tilting forward and also
diagonal to avoid appliance moving sideways.
Gas leakage and operation of the appliance must be tested by the installer before leaving. Check all burner flames are blue
in colour, stable and completely ignite at both high and low flame settings with no appreciable yellow tipping, carbon
deposition, lifting, floating, lighting back or objectionable odour. Test burners individually and in combination.
Where the data plate is obscured by cabinetry when the cooker is in the installed position, place the supplied duplicate
data plate to a suitable adjacent surface or within the instruction manual for future reference.
THE MANUFACTURER DECLINES ANY AND ALL RESPONSIBILITIES FOR DAMAGES TO THINGS
OR INJURIES TO PERSONS OR ANIMALS DERIVING FROM INCORRECT INSTALLATION OR USE
OF THE EQUIPMENT.
5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents