I. Specifications
A. Electrical and Refrigerant Data
The rating label and nameplate provide electrical and refrigerant data. The rating label
can be seen by removing the front panel. The nameplate is located on the rear panel. For
certification marks, see the nameplate.
We reserve the right to make changes in specifications and design without prior notice.

1. KM-1100M_H

Model Number
KM-1100MAH
AC Supply Voltage
208-230/60/1
Compressor
208-230V 9.0RLA 56LRA
Pump
120V 1.2FLA 60W
Fan
115V 2FLA (TOTAL) 1/15HP --- --- ---
Other
115-120V 0.3A
Maximum Fuse Size 20 AMPS
Max. HACR Breaker
20 AMPS
(USA Only)
Max. Circuit Breaker
20 AMPS
(Canada Only)
Minimum Circuit
20 AMPS
Ampacity
Design Pressure
HI-467PSI LO-230PSI
Refrigerant
404A 3 LB. 15.4 OZ.

2. KM-1340M_H

Model Number
KM-1340MAH
AC Supply Voltage
208-230/60/1 (3 Wire with
Neutral)
Compressor
208-230V 9.5RLA 61LRA 208-230V 9.2RLA 61LRA 208-230V 9.5RLA 61LRA
Pump
120V 1.2FLA 60W
Fan
115V 2FLA (TOTAL) 60W --- --- ---
Other
115-120V 0.3A
Maximum Fuse Size 20 AMPS
Max. HACR Breaker
20 AMPS
(USA Only)
Max. Circuit Breaker
20 AMPS
(Canada Only)
Minimum Circuit
20 AMPS
Ampacity
Design Pressure
HI-467PSI LO-206PSI
Refrigerant
404A 4 LB. 11.4 OZ.
Single Phase
KM-1100MWH
208-230/60/1
208-230V 8.0RLA 56LRA 208-230V 8.0RLA 56LRA
120V 1.2FLA 60W
115-120V 0.3A
20 AMPS
20 AMPS
20 AMPS
20 AMPS
HI-427PSI LO-230PSI
404A 1 LB. 10.5 OZ.
Single Phase
KM-1340MWH
208-230/60/1 (3 Wire with
Neutral)
120V 1.2FLA 60W
115-120V 0.3A
20 AMPS
20 AMPS
20 AMPS
20 AMPS
HI-427PSI LO-230PSI
404A 2 LB. 1.5 OZ.
6
KM-1100MRH
208-230/60/1
120V 1.2FLA 60W
120V 3A MAX (Fans in URC)
115-120V 0.3A
20 AMPS
20 AMPS
20 AMPS
20 AMPS
HI-467PSI LO-230PSI
404A
Total Refrigerant Charge with
Hoshizaki Remote Condenser
Unit URC-14F: 9 LB. 11.2 OZ.
KM-1340MRH
208-230/60/1 (3 Wire with
Neutral)
120V 1.2FLA 60W
120V 3A MAX (Fans in URC)
115-120V 0.3A 60W
20 AMPS
20 AMPS
20 AMPS
20 AMPS
HI-467PSI LO-206PSI
404A
Total Refrigerant Charge with
Hoshizaki Remote Condenser
Unit URC-14F: 9 LB. 14 OZ.

Advertisement