4) Remove the front insulation panel, then slide the cube guide to the right. Remove the
rubber cap and sleeve covering the overflow pipe. See Fig. 16. Unscrew the overflow
pipe. After the water tank has drained, reconnect the overflow pipe. Replace the rubber
cap, sleeve, cube guide, and front insulation panel. NOTICE! Make sure the O-ring is
attached to the bottom of the overflow pipe and be careful not to cross thread the
overflow pipe.
5) To fill the water tank, move the control switch to the "ICE" position, then replace the front
panel. After 3.5 min., remove the front panel, then move the control switch to the "OFF"
position.
6) Remove the front insulation panel, then pour 30 fl. oz. (887 ml) of Hoshizaki "Scale
Away" into the water tank. Replace the front insulation panel. Turn the cleaning valve to
the left until completely vertical (open).
7) NOTICE! To avoid excessive foaming, wait 1 min. before proceeding.
After 1 min., move the control switch to the "WASH" position, then replace the front
panel.
8) After 30 min., remove the front panel, then move the control switch to the "OFF"
position.
9) Remove the front insulation panel, then slide the cube guide to the right. Remove the
rubber cap and sleeve covering the overflow pipe. Unscrew the overflow pipe. After the
water tank has drained, reconnect the overflow pipe. Replace the rubber cap, sleeve,
cube guide, and front insulation panel.
10) In bad or severe water conditions, turn off the power supply, then remove, clean
(cleaning solution = 5 oz. Hoshizaki "Scale Away" per gallon of warm water), rinse,
and replace the cube guides, float switch, water supply tubes, spray tubes, and spray
guides; turn on the power supply when complete. Otherwise, continue to step 11..
Cleaning Rinse
11) Turn the cleaning valve to the right until completely horizontal (closed). Move the control
switch to the "ICE" position, then replace the front panel. After 3.5 min., remove the front
panel, then move the control switch to the "OFF" position. Note: The icemaker will not
operate unless the cleaning valve is completely closed.
12) Turn the cleaning valve to the left until completely vertical (open). Move the control
switch to the "WASH" position, then replace the front panel. After 5 min., remove the
front panel, then move the control switch to the "OFF" position.
13) Remove the front insulation panel, then slide the cube guide to the right. Remove the
rubber cap and sleeve covering the overflow pipe. Unscrew the overflow pipe. After the
water tank has drained, reconnect the overflow pipe. Replace the rubber cap, sleeve,
cube guide, and front insulation panel.