Download Print this page

Technibel KAF96R5IA Series Installation Instructions Manual page 23

Advertisement

L
M
N
Floor installation.
EG
Attach the bracket to the wall with the screws, but do not tighten the screws all
the way, so that you can move the bracket for final adjustment. Adjust the bracket
as shown in the figure, then finish tightening the screws. Hang the unit on the
bracket as shown in the figure.
Installazione a pavimento.
I
Fissare la staffa al muro senza però avvitarla a fondo, in modo da poterne rifinire
successivamente la posizione. Regolare la staffa come mostrato in figura e
stringere definitivamente le viti. Appendere l'unità alla staffa, come mostrato in
figura.
Installation à plafond.
F
Fixez l'étrier au mur à l'aide des vis, mais ne serrez pas celles-ci complètement,
afin de pouvoir ajuster la position de l'étrier lors de la fixation définitive. Ajustez
l'étrier comme indiqué sur la figure, puis serrez les vis à fond. Accrochez l'appareil
sur l'étrier comme indiqué sur la figure.
D
Installation auf dem Boden.
Bringen Sie die Halterung an der Wand mit den Schrauben an. Ziehen Sie diese
jedoch nicht vollständig an, damit Sie die Halterung in die endgültige Position
bringen können. Richten Sie die Halterung aus, wie in Abbildung gezeigt ist,
ziehen Sie dann die Schrauben fest. Hängen Sie das Gerät an die Halterung,
wie gezeigt in Abbildung.
E
Instalación en el suelo.
Fijiar la abrazadera en la pared sin atornillarla completamente para que se
pueda mover. Ajustarla bien, como se muestra en la figura, y atornillar hasta el
fondo. Colgar la unidad en la abrazadera.
Remove the electrical box cover to operate on the terminal strip.
EG
Rimuovere il coperchio scatola componenti elettrici per accedere alla
I
morsettiera.
Enlever le capot du coffret électriques pour agir sur la boîte à bornes.
F
Die Abdeckplatte des Klammbrettes entfernen.
D
Quitar la tapa de la caja de los componentes eléctricos para acceder a regleta
E
de bornes.
Predispose the terminals of the wire to connect to the terminal strip and connect
EG
them. (See electric wiring to connect).
Secure inter-unit wire using the supplied clamp.
WARNING
Loose wiring may cause the terminal to overheat or result in unit
malfunction.
A fire hazard may also exist. Therefore, be sure all wiring is tightly
connected.
When closing the electrical component box, take care not to leave part of
the wires out or let them get caught between the lid and the unit. Check
to see that the tab is aligned, then tighten the screw.
Predisporre il cavo elettrico per il collegamento alla morsettiera e collegarlo.
I
(Vedere schema per l'allacciamento).
Bloccare il cavo al fissacavo della flangia.
AVVERTIMENTO
Accertarsi che i terminali dei cavi elettrici siano ben stretti sulla morsettiera.
Terminali non stretti causano surriscaldamento alla morsettiera, problemi
al funzionamento del condizionatore d'aria con pericolo di inizio d'incendio.
Nel chiudere la scatola componenti elettrici, controllare che i fili non
fuoriescano o non rimangano bloccati fra il coperchio e l'unità. Controllare
che la linguetta sia allineata e stringere le viti.
7