Start Up Display; Standard Display Functions - NewArc Mig500 Operational Manual

Table of Contents

Advertisement

By default both the current and voltage displays show four dashes when not welding. When
current flows, panel shows actual current and voltage on display.
Every other function is accessible by short pressing encoder down and turning encoder anti- or
clockwise for the correct value.

3.1 Start up Display

4.2.4 Start-up Display
P.5.9.8.
1
8.1.0.0.
L.S.-. 1.
2
8.5.0.0.
L.S.-.2.
3
8.3.0.0.
L.S.-.3.
4
8.4.0.0.
SECTION 4 — OPERATION

3.2 Standard Display Functions

4.2.5 Standard display functions
8.8.8.8
5
8.8.8.8.
8.8.8.8
6
*
8.8.8.8.
8.8.8.8.
7
8.8.8.8
*
_._._.U.
8
8.3.3.A
*
~.~.~.U.
9
8.3.3.A
*
1.0.0.U
10
*
8.3.3.A
*
1.0.0.U.
11
8.3.3.A.
-.-.-.-.
12
-.-.-.-.
d.u.r.8.
13
8. 1. 1.3.
d.u.r.8.
14
C.L.r.8.
14
MIG 500
Program no. and version display
Settings Check
Maximum current set for MMA mode
(This mode not available on MIG 400)
Settings Check
Maximum current set for MIG mode
Settings Check
Maximum current set for TIG mode
(This mode not available on MIG 400)
Top, right decimal point constantly ON
Power Source
Top, right decimal point flashing
Bottom, right decimal point flashing
Dashes on the bottom of the voltage display and
current flow diode flashing
Dashes on the top of the voltage display and cur-
rent flow diode flashing
Voltage and current display with
U and A characters
Voltage and current display with flashing U and A
characters
Change mode
Welding time duration
Only during display start
Function accessible when encoder button
This is info only, no changes are possible.
LED4 (bottom) is flashing when mode is
available (mode availability is specified by
MIG400
Output voltage detected (when output volt-
Current flow detected (when current flow
Current flow and output voltage too low
Current flow and output voltage too high
Average welding conditions from the last
job. That function is automatically displayed
after stop current flow but is also accessible
Minimum current flow time to activate func-
Mode is selected by turning encoder. Cur-
rently selected mode is indicated by one of
After long press counter is resetting and mes-
press long during start-up.
software version)
Restart is necessary to stop display
Remote control detected
age >5V and no remote connected)
>5A)
(<5V)
(>50V)
Actual current and voltage readings
as a menu function.
tion is 5s
the LED diodes
Personal time counter in minutes.
Every decimal point = 6min
Maximum value 999.9min
Long press to reset value
sage "dur.clr" displayed for short time