Electrical Data - Technibel Climatisation GR72R5TA Installation Instructions Manual

Compact wall-mounted split units

Advertisement

Installation site selection - Indoor unit
AVOID
• Direct sunlight.
• Nearby heat sources that may affect unit performance.
• Areas where leakage of flammable gas may be expected.
• Locations where large amounts of oil mist may occur (such as
in kitchen or near factory equipment) because oil contamination
can cause operation problems and may deform plastic surfaces
and parts of the unit.
• Unsteady locations that will cause noise or possible water
leakage.
• Locations where the remote control unit will be splashed with
water or affected by dampness or humidity.
• To make holes in areas where electrical wiring or conduits are
located.
DO
• Select an appropriate position from which every corner of the
room can be uniformily cooled.
ADDITIONAL MATERIAL REQUIRED FOR INSTALLATION (NOT SUPPLIED)
G
Deoxidized annealed copper tube for refrigerant tubing connecting the units of the system; it has to be insulated with foamed polyethylene
(min. thickness 8mm).
MODEL
OUTER DIAMETER
MCA/MCAV7X - MCA/MCAV9X
MCA/MCAV12X
G
PVC pipe for condensate drain pipe (ø int.18mm) in lenght suitable to let the condensate flow into the outside drainage.
G
Anti-freeze oil for flare connections (about 30g).
G
Electric wire: use insulated copper wires of size and length as shown at paragraph "SYSTEM WIRING DIAGRAMS".

ELECTRICAL DATA

MODEL
Cross section area (mm
2
)
GR7X - GRV7X
GR9X - GRV9X
GR12X - GRV12X
TUBING LENGTH AND ELEVATION DIFFERENCE LIMITS
MAX. ALLOWABLE
TUBING LENGTH AT
MODEL
MCA/MCAV7X - MCA/MCAV9X
MCA/MCAV12X
* If total tubing length becomes a) 7,5 to 15m, b) 7,5 to 20m (max.), charge additional refrigerant by a) 15; by b) 25g/m.
No additional charge of compressor oil is necessary.
NARROW TUBE
MIN. THICKNESS
6,35 mm
6,35 mm
LENGTH, SIZE WIRES AND DELAYED FUSE
Power supply wiring length
("A") m
1,5
10
10
3
H
LIMIT OF TUBING
SHIPMENT
(m)
7.5
7.5
• Select a sufficiently strong location to support the weight of the
unit.
• Select a location where tubing and drain hose have the shortest
run to the outside.
• Allow access for operation and maintenance as well as
unrestricted air flow around the unit.
Installation site selection - Outdoor unit
AVOID
• Heat sources, exhaust fans.
• Direct sunlight.
• Damp, humid or uneven locations.
• To make holes in areas where electrical wiring or conduits are
located.
DO
• Choose places as cool as possible and well ventilated.
• use lug bolts or equal to bolt down the unit, reducing vibration
and noise.
OUTER DIAMETER
0,8 mm
9,52 mm
0,8 mm
12,7 mm
Power line length
("B") m
1,5
20 m
LIMIT OF ELEVATION
LENGTH
DIFFERENCE
(m)
15
20
3
LARGE TUBE
MIN. THICKNESS
0,8 mm
0,8 mm
Delayed fuse
10A
H
REQUIRED AMOUNT OF
ADDITIOONAL
H
REFRIGERANT
(m)
(g / m)*
7
a) 15
7
b) 25
EG
(go on page 4)