Toshiba ETB004Z Instruction Manual

Toshiba expansion io card option 2 instruction manual

Advertisement

Quick Links

Expansion IO Card Option 2
ETB004Z Instruction manual
1. Make sure that this instruction manual is delivered to the end user of the expansion
IO card option.
2. Read this manual before installing or operating the expansion IO card option. Keep
it in a safe place for reference.
3. All information contained in this manual are subject to change without notice.
Please confirm the latest information on our web site "www.inverter.co.jp".
NOTICE
E6581341

Advertisement

Table of Contents
loading

Summary of Contents for Toshiba ETB004Z

  • Page 1 Expansion IO Card Option 2 ETB004Z Instruction manual 1. Make sure that this instruction manual is delivered to the end user of the expansion IO card option. 2. Read this manual before installing or operating the expansion IO card option. Keep it in a safe place for reference.
  • Page 2: Safety Precautions

    Safety precautions On the inverter and in its instruction manual, important information is contained for preventing injuries to users and damages to assets and for proper use of the device. Read the instruction manual attached to VF-AS1/PS1 along with this instruction manual for completely understanding the safety precautions and adhere to the contents of these manuals.
  • Page 3: Safety Precaution

    ▼ Do not attach this option to any inverter other than the VF-AS1/PS1. Doing so could result in electric shock or fire. ▼ Don't place or insert any kind of object into the ETB004Z (electrical wire cuttings, rods, wires). Prohibited Doing so could result in electric shock or fire.
  • Page 4 ■ Wiring ▼ Electrical construction work must be done by a qualified expert. Installation or connection of input power by someone who does not have that expert knowledge may result in fire or electric shock. ▼ Shut off power when installing and wiring this option. Wait at least 15 minutes and check to make sure that the charge lamp (VF-AS1/PS1) is Mandatory no longer lit.
  • Page 5 Introduction Thank you for purchasing a “Expansion IO card option 2” for industrial inverter TOSVERT VF-AS1/PS1 inverter. By the use of this option, the expansion of input/output terminal is possible. This instruction manual describes connecting method and usage of the “Expansion IO card option”.
  • Page 6: Table Of Contents

    Contents 1. Name and function of each section ... 6 1.1. Appearance ...6 1.2. Name of each section (terminal) ...6 2. Installing the IO card option in the VF-AS1/PS1... 7 2.1. Connection to the inverter ...7 2.2. Wiring ...8 3. Functional description ... 10 3.1.
  • Page 7: Name And Function Of Each Section

    1. Name and function of each section Following figure shows appearance and name of each section of the expansion IO card option. 1.1. Appearance SINK/SOURCE Select SW SOURCE SINK(PLC) SINK(INT) 1.2. Name of each section (terminal) Programmable relay output 2 Programmable relay output 2 Programmable relay output 2 Analog input setting power output -10V...
  • Page 8: Installing The Io Card Option In The Vf-As1/Ps1

    2. Installing the IO card option in the VF-AS1/PS1 2.1. Connection to the inverter (1) Turn off input power before installing. Turn off the input power of VF-AS1/PS1 and wait for at least 15 minutes and then check that the CHARGE lamp on VF-PS1 is no longer lit. Mandatory (2) Securing the option to the inverter a) Insert a flat-blade screwdriver in each of the two holes at the upper part of the front...
  • Page 9: Wiring

    2.2. Wiring When conducting wiring, follow the instructions below. • Use shield wire for control signal line and ground the unit with shield wire (Use twisted pair shield cable for wiring of the analog monitor output.) • Never bind the signal line and main circuit connection wire together. •...
  • Page 10 Terminal Function symbol TH2+ Thermal trip input TH2- -10V power supply Multifunction OUT5 programmable OUT6 open collector output. Common to input/output AI1+ Differential current AI1- input AI2+ Analog input MON1 Monitor output MON2 Pulse train input Electrical specification The resistance between TH2+ and TH2- Tripping value: about under 50 ohm or over 3k ohm...
  • Page 11: Functional Description

    In this section, functions added by the installation of this expansion IO card option, on top of the standard inverter functions, are described. Note: When power on or reset the inverter, the initialization of the ETB004Z terminal inputs and outputs are delayed about 300ms from the inverter own terminals.
  • Page 12: Multi-Function Input Terminal

    3.2. Multi-function input terminal Four output terminals can be added. Function is similar to that of the input terminals of the inverter, so refer to the inverter instruction manual. Parameter Title f123 Input terminal selection 13 (LI5) f124 Input terminal selection 14 (LI6) f125...
  • Page 13: Multi-Function Analog Output

    3.4. Multi-function analog output MON1, MON2 terminal output +/-10V, 0 - 10V, 0 - 20mA (4 - 20mA) analog signal. Example : MON1 output (0 - 10V) Bias adjustment: f690 Parameter Title Function f672 MON1 terminal meter selection f673 MON1 terminal meter adjustment f674...
  • Page 14: Analog Input (Ai2)

    Parameter Title f222 AI1 input point 1 setting f223 AI1 input point 1 frequency f224 AI1 input point 2 setting f225 AI1 input point 2 frequency f226 * AI1 input point 1 rate f227 * AI1 input point 2 rate Optional AI1 input bias f476 Optional AI1 input gain...
  • Page 15: Pulse Train Input (Rp)

    Expansion IO card option TH2+ thermistor TH2- 3.8. Pulse train input (RP) The frequency command can be input from the pulse train input. Parameter Title fmod Frequency setting mode selection 1 f234 RP/high speed pulse input point 1 setting f235 RP/high speed pulse input point 1 frequency f236...
  • Page 16: External Diagram

    E6581341 4. External diagram Do not forget to reserve the space for the options at time of installation. External diagram of option (unit: mm) Dimension of optional unit The control panel depth increases about 21.6mm when the option is installed. Secure the front space from the inverter control panel fully.
  • Page 17: Specification

    5. Specification <Environment Specification> Item Indoor, less than 3,000 m from the sea level. Use Environment No direct sunlight, corrosive or explosive gas, steam, cutting dusts or dusts, grinding solution, and grinding oil. Ambient Temperature -10 to +60℃ Storage Temperature -25 to +65℃...
  • Page 18: Warranty

    6. Warranty TOSHIBA provides warranty with the product under the following conditions. 1. If and when a trouble occurs on the option unit properly installed and handled within one year of delivery, and if the trouble is clearly attributable to defects inherent in our design and manufacture, the product will be repaired free of charge.