Toshiba ETB003Z Instruction Manual
Toshiba ETB003Z Instruction Manual

Toshiba ETB003Z Instruction Manual

Expansion io card option 1

Advertisement

Quick Links

Expansion IO Card Option 1
ETB003Z Instruction manual
1. Make sure that this instruction manual is delivered to the end user of the expansion
IO card option.
2. Read this manual before installing or operating the expansion IO card option. Keep
it in a safe place for reference.
1. Make sure that this instruction manual is delivered to the end user of the
3. All information contained in this manual are subject to change without notice.
expansion IO card option.
Please confirm the latest information on our web site "www.inverter.co.jp".
this manual before installing or operating the inverter unit, and store it in a
© Toshiba Schneider Inverter Corporation 2005
NOTICE
NOTE
All rights reserved.
E6581339⑥

Advertisement

Table of Contents
loading

Summary of Contents for Toshiba ETB003Z

  • Page 1 3. All information contained in this manual are subject to change without notice. expansion IO card option. Please confirm the latest information on our web site “www.inverter.co.jp”. this manual before installing or operating the inverter unit, and store it in a © Toshiba Schneider Inverter Corporation 2005 NOTICE NOTE All rights reserved.
  • Page 2: Safety Precautions

    Safety precautions On the inverter and in its instruction manual, important information is contained for preventing injuries to users and damages to assets and for proper use of the device. Read the instruction manual attached to VF-AS1/PS1 along with this instruction manual for completely understanding the safety precautions and adhere to the contents of these manuals.
  • Page 3: Safety Precaution

    ▼ Do not attach this option to any inverter other than the VF-AS1/PS1. Doing so could result in electric shock or fire. ▼ Don't place or insert any kind of object into the ETB003Z (electrical wire cuttings, rods, wires). Prohibited Doing so could result in electric shock or fire.
  • Page 4 ■ Wiring ▼ Electrical construction work must be done by a qualified expert. Installation or connection of input power by someone who does not have that expert knowledge may result in fire or electric shock. ▼ Shut off power when installing and wiring this option. Wait at least 15 minutes and check to make sure that the charge lamp (VF-AS1/PS1) Mandatory is no longer lit.
  • Page 5 Introduction Thank you for purchasing a “Expansion IO card option 1” for industrial inverter TOSVERT VF-AS1/PS1 inverter. By the use of this option, the expansion of input/output terminal is possible. This instruction manual describes connecting method and usage of the “Expansion IO card option”.
  • Page 6: Table Of Contents

    Contents 1. Name and function of each section ... 1.1 Appearance ...6 1.2 Name of each section (terminal) ...6 2. Installing the IO card option in the VF-AS1/PS1... 2.1 Connection to the inverter ...7 2.2 Wiring ...8 3. Functional description ... 3.1 Multi-function output terminal ...10 3.2 Multi-function input terminal ...11 3.3 -10V power supply...11...
  • Page 7: Name And Function Of Each Section

    1. Name and function of each section Following figure shows appearance and name of each section of the expansion IO card option. 1.1 Appearance 1.2 Name of each section (terminal) P24/PLC TH1+ TH1- OUT3 OUT4 Inverter cover hook for the fixation SINK/SOURCE Select SW Programmable relay output 1 Programmable relay output 1...
  • Page 8: Installing The Io Card Option In The Vf-As1/Ps1

    2. Installing the IO card option in the VF-AS1/PS1 2.1 Connection to the inverter (1) Turn off input power before installing. Turn off the input power of VF-AS1/PS1 and wait for at least 15 minutes and then check that the CHARGE lamp on VF-AS1/PS1 is no longer lit. Mandatory (2) Securing the option to the inverter a) Insert a flat-blade screwdriver in each of the two holes at the upper part of the front...
  • Page 9: Wiring

    2.2 Wiring When conducting wiring, follow the instructions below. • Use shield wire for control signal line and ground the unit with shield wire (Use twisted pair shield cable for wiring of the analog monitor output.) • Never bind the signal line and main circuit connection wire together. •...
  • Page 10 Terminal Function symbol TH1+ Thermal trip input TH1- -10V power upply Multifunction OUT3 programmable OUT4 open collector output. Common to input/output Electrical specification The resistance between TH1+ and TH1- Tripping value: about under 70 ohm or about over 2.5k ohm Reset value: about 1.6k ohm DC-10V - 10mA Open collector output...
  • Page 11: Functional Description

    3. Functional description In this section, functions added by the installation of this expansion IO card option, on top of the standard inverter functions, are described. * If the software version of inverter is less than V104, when OUT3 or OUT4 terminals is set as negative logic, it may output a flash pulse at inverter reset.
  • Page 12: Multi-Function Input Terminal

    3.2 Multi-function input terminal Four output terminals can be added. Function is similar to that of the input terminals of the inverter, so refer to the inverter instruction manual. Parameter Title Input terminal selection 9 (LI1) f119 Input terminal selection 10 (LI2) f120 Input terminal selection 11 (LI3) f121...
  • Page 13: External Thermal Trip Input (Th1+, Th1-)

    3.4 External thermal trip input (TH1+, TH1-) By connecting the thermistor to TH1+ and TH1- terminal, when the thermistor value is unusual, the inverter can be trip. The resistor value between TH1+ and TH1- about under 70 ohm about 70 - about 2.5k ohm about 1.6k ohm about 3k ohm Parameter...
  • Page 14: External Diagram

    E6581339⑥ 4. External diagram Do not forget to reserve the space for the options at time of installation. External diagram of option (unit: mm) Dimension of optional unit The control panel depth increases about 21.6mm when the option is installed. Secure the front space from the inverter control panel fully.
  • Page 15: Specification

    5. Specification <Environment Specification> Item Indoor, less than 3,000 m from the sea level. Use Environment No direct sunlight, corrosive or explosive gas, steam, cutting dusts or dusts, grinding solution, and grinding oil. Ambient Temperature -10 to +60℃ Storage Temperature -25 to +65℃...
  • Page 16: Warranty

    6. Warranty TOSHIBA provides warranty with the product under the following conditions. 1. If and when a trouble occurs on the option unit properly installed and handled within one year of delivery, and if the trouble is clearly attributable to defects inherent in our design and manufacture, the product will be repaired free of charge.

Table of Contents