OPERATION MANUAL Packaged air-cooled water chillers and packaged reversible air to water heat pumps EWAQ005AAV3P EWAQ006AAV3P EWAQ007AAV3P EWYQ005AAV3P EWYQ006AAV3P EWYQ007AAV3P...
Before operating the unit, make sure the installation has NOTE Some functions described in this manual may not be been carried out correctly by a professional Daikin dealer. available or should not be available. Ask your installer or your local Daikin dealer for more information on If you feel unsure about operation, contact your Daikin permission levels.
This icon indicates that the OFF action is selected when programming the schedule timer. INSPECTION REQUIRED k and l These icons indicate that inspection is required on the installation. Consult your Daikin Dealer. EWAQ+EWYQ005~007AAV3P Operation manual Packaged air-cooled water chillers and...
SCHEDULE TIMER BUTTON r/p Setting up the controller The main function of this multi-purpose button is to enable/ disable the schedule timer. The button is also used to program the controller. The function of After initial installation, the user can set the clock and day of the the button depends on the actual status of the controller or on week.
(contact your local Daikin dealer). Selecting silent mode operation (s Defrost operation restarts automatically when the Use the s button to activate silent mode operation (s).
The schedule timer is enabled ( icon displayed) or disabled ( icon Programming and consulting the schedule not displayed), by pressing the pr button. timer Only use the pr button to enable or disable the NOTE schedule timer. The schedule timer overrules the o button.
Page 7
Programming Programming cooling or heating is carried out as follows. Use the = button to select the operation mode (cooling or Programming cooling or heating heating) you want to program. Press the < button. The actual mode is blinking. Use the pi and pj buttons to select the mode (current mode or silent mode) you want to program.
Page 8
Programming silent mode 10 Press the < button for 5 seconds to store the programmed actions. If the < button is pressed when action number 3 is displayed, actions 1, 2 and 3 are stored but 4 and 5 are deleted. You automatically return to step 4.
This maintenance should be actions of a specific day to the next day (e.g. copy all programmed carried out by your local Daikin technician. actions from "1" to "2"). Besides keeping the remote controller clean by means of a soft damp To copy programmed actions to the next day, proceed as follows: cloth, no maintenance is required by the operator.