A. Vent Components Diagrams (continued)
Note: Heat shields MUST overlap by a minimum of 1-1/2 in. (38 mm). The heat shield is designed to be
used on a wall 4 in. to 7-1/4 in. (102 mm to 184 mm) thick. If wall thickness is less than 4 in. (102 mm)
the existing heat shields must be field trimmed. If wall thickness is greater than 7-1/4 in. (184 mm) a
DVP-HSM-B will be required.
15-1/8 in.
(384 mm)
12 in.
(305 mm)
6-11/16 in.
(169 mm)
3-15/16 in.
(101 mm)
8 in.
(203 mm)
14-7/16 in.
14-7/16 in.
367 mm
Wall Thimble-Black
Figure 12.2 SLP Series Vent Components
64
Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. L • 4/19
8 in.
(203 mm)
SLP-TRAP
Horizontal Termination Cap
3-13/16 in.
(97 mm)
SL-2DVP
Adapter
367 mm
2-5/16 in.
59 mm
SLP-WT-BK
Heat
Shield
Term Cap
Max
Effective
Trap1
Length
Trap2
3-15/16 in.
(101 mm)
5-1/16 in.
(128 mm)
12-5/8 IN.
(321 mm)
Minimum
Maximum
Effective Length
Effective Length
3-1/8 in.
4-3/4 in.
79 mm
121 mm
5-1/4 in.
9-1/4 in.
133 mm
235 mm
26 in.
660 mm
DVP-HSM-B
Extended Heat Shield
12-5/8 IN.
(321 mm)
10-5/8 IN.
(270 mm)
SLP-RDS
ROOF DECK INSULATION SHIELD
20 IN.
(508 mm)