High pressure icp ballistic pressure sensor, 80k psi, 0.07 mv/psi, accel. comp. (ceramic coated integral diaphragm) (13 pages)
Summary of Contents for PCB Piezotronics 103B01
Page 1
Model 103B01 Acoustic ICP® Pressure Sensor Installation and Operating Manual For assistance with the operation of this product, contact PCB Piezotronics, Inc. Toll-free: 800-828-8840 24-hour SensorLine: 716-684-0001 Fax: 716-684-0987 E-mail: info@pcb.com Web: www.pcb.com...
Page 2
Piezotronics, user servicing or repair is critical test. not recommended and, if attempted, may void the factory warranty. Routine PCB Piezotronics maintains an ISO- maintenance, such as the cleaning of 9001 certified metrology laboratory and electrical connectors, housings, and offers calibration services, which are...
Page 3
E-mail: info@pcb.com representative. Warranty – All equipment and repair services provided by PCB Piezotronics, Inc. are covered by a limited warranty against defective material workmanship for a period of one year from date of original purchase. Contact...
Page 5
Component Name Hazardous Substances Lead Mercury Cadmium Chromium VI Polybrominated Polybrominated (Pb) (Hg) (Cd) Compounds Biphenyls Diphenyl (Cr(VI)) (PBB) Ethers (PBDE) Housing PCB Board Electrical Connectors Piezoelectric Crystals Epoxy Teflon Electronics Thick Film Substrate Wires Cables Plastic Solder Copper Alloy/Brass This table is prepared in accordance with the provisions of SJ/T 11364.
Page 6
OPERATION MANUAL FOR MICROPHONE Series 103A DESCRIPTION The Series 103A microphones are high-sensitivity pressure sensors featuring miniature size, built-in solid state electronics and acceleration compensation. The Model 103A (see installation drawing) has pigtail leads extending radially from the side of the unit and has a nominal sensitivity of 1500 mV/psi.
OPERATION MANUAL FOR MICROPHONE Series 103A The result is a two-wire system, precluding the need for multi-conductor cabling. VIEW FROM A second diaphragm, located behind the pressure DIAPHRAGM diaphragm and attached to another bimorph bender WHITE crystal acting in opposition to the pressure crystal, READOUT provides acceleration compensation to the Series BLUE (N.C.)
The 103A Series Sensors must be dynamically calibrated using a known step function or pulse, or overpressure (see specs with a microphone calibrator. maximum pressure), to do so may change the calibration. ®ICP is a registered trademark of PCB Piezotronics Drawing Number: 21082 Revision: NR...
Page 9
Model Number Revision: C ACOUSTIC ICP® PRESSURE SENSOR 103B01 ECN #: 40794 Performance ENGLISH OPTIONAL VERSIONS Measurement Range 3.00 psi 180.3 dB Optional versions have identical specifications and accessories as listed for the standard model Useful Overrange 6.00 psi 186.3 dB except where noted below.