Pinnacle Remington REM-40-GFA-B User's Manual & Operating Instructions

Pinnacle Remington REM-40-GFA-B User's Manual & Operating Instructions

Propane forced air heater
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

REM-40-GFA-B / REM-60V-GFA-B / REM-125V-GFA-B / REM-150V-GFA-B
Locating Your Serial Number:
Your serial number can be found on a white label on the right side cover of your heater. It will be-
gin with the letter "G" followed by 9 digits. For Example: G123456789. Have your Serial Number
ready before calling customer service at 800-641-6996.
DANGER
RIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE, EXPLO-
SION, BURN. ASPHYXIATION, CARBON MONOXIDE POISONING AND / OR ELECTRIC SHOCK.
ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE
OR SERVICE THIS HEATER. IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS
AN INSTRUCTIONS MANUAL, LABEL, ETC. CONTACT THE MANUFACTURER.
WARNING
CARDBOARD, A SAFE DISTANCE AWAY FROM THE HEATER AS REC-
OMMENDED BY THESE INSTRUCTIONS. NEVER USE THE HEATER IN
SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE COM-
BUSTIBLES, OR PRODUCTS SUCH AS GASOLINE, SOLVENTS, PAINT
THINNERS, DUST PARTICLES OR UNKNOWN CHEMICALS.
MODEL NUMBERS:
CONSUMER: READ AND SAVE THESE INSTRUCTIONS
GENERAL HAZARD WARNING:
FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUC-
TIONS PROVIDED WITH THIS HEATER, CAN RESULT IN DEATH, SE-
FIRE, BURN, INHALATION, AND EXPLO-
SION HAZARD. KEEP SOLID COMBUSTIBLES,
SUCH AS BUILDING MATERIALS, PAPER OR
Fax: 320-251-2922 • Web:
PROPANE FORCED AIR HEATER
User's Manual &
Operating Instructions
1 Industrial Blvd #101, Sauk Rapids, MN 56379 USA • Toll Free
www.remingtonheater.com
© 2018 Pinnacle Climate Technologies, Inc.
Factory ID: 001
(800) 641-6996
• Email: info@pinnacleclimate.com
RBGC-403

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Remington REM-40-GFA-B and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Pinnacle Remington REM-40-GFA-B

  • Page 1 BUSTIBLES, OR PRODUCTS SUCH AS GASOLINE, SOLVENTS, PAINT THINNERS, DUST PARTICLES OR UNKNOWN CHEMICALS. 1 Industrial Blvd #101, Sauk Rapids, MN 56379 USA • Toll Free (800) 641-6996 Fax: 320-251-2922 • Web: www.remingtonheater.com • Email: info@pinnacleclimate.com © 2018 Pinnacle Climate Technologies, Inc. RBGC-403...
  • Page 2: Table Of Contents

    IF YOU HAVE ANY QUESTIONS ABOUT APPLICATIONS. Other standards govern the use of fuel gasses and heating products for specific uses. Your local authority can advise you about these. © 2018 Pinnacle Climate Technologies, Inc. Propane Forced Air Heater User’s Manual...
  • Page 3: Safety Information

    100,000 Btu / Hr (29 kW) heater TOUCH. KEEP CHILDREN, ANIMALS, CLOTH- rating. Refer to “Ventilation” on page 8 for further ING AND COMBUSTIBLES AWAY FROM HEATER. instructions. © 2018 Pinnacle Climate Technologies, Inc. Propane Forced Air Heater User’s Manual...
  • Page 4: Unpacking

    2. Remove all items from carton used without alteration. 3. Check all items for shipping damage. If the heater is damaged, promptly inform dealer where you purchased the heater. © 2018 Pinnacle Climate Technologies, Inc. Propane Forced Air Heater User’s Manual...
  • Page 5: Specifications

    Specifications subject to change without notice. FEATURES Handle Outer Shell Guard Inner Shell Power Cord Height Controller Gas Valve Knob Base WHAT’S IN THE BOX Hose & Regulator Assembly (1) Heater (1) © 2018 Pinnacle Climate Technologies, Inc. Propane Forced Air Heater User’s Manual...
  • Page 6: Operation

    – Tightly close the gas shutoff valve on the LP cylinder after each use. – All fittings must be protected when disconnected from the LP cylinder. © 2018 Pinnacle Climate Technologies, Inc. Propane Forced Air Heater User’s Manual...
  • Page 7 LP gas industry procedures. Failure to follow and re-connect the leaking connection. If the these instructions may result in explosion, leak persists after several tries, contact Pinnacle fire, severe personal injury or death. Customer Service at 800-641-6996. The installation of this heater must meet all local –...
  • Page 8: Ventilation

    (2,800 sq. cm) for each 100,000 BTU / Hr (29 kW). of heater output. Provide a larger opening if more heaters are being used. © 2018 Pinnacle Climate Technologies, Inc. Propane Forced Air Heater User’s Manual...
  • Page 9: Storage/Maintenance

    WIRING DIAGRAMS 40-GFA Figure 6 60V-GFA / 125V-GFA / 150V-GFA © 2018 Pinnacle Climate Technologies, Inc. Propane Forced Air Heater User’s Manual...
  • Page 10: Troubleshooting Guide

    2. Damaged control valve. 2. Replace control valve. 3. Dust or debris accumulated in heater. 3. Clean inside of heater. © 2018 Pinnacle Climate Technologies, Inc. Propane Forced Air Heater User’s Manual...
  • Page 11: Exploded View

    22-521-0001 22-521-0002 22-521-0002 22-521-0002 PCB Case 22-506-0001 22-506-0001 22-506-0001 22-506-0001 Valve Knob 22-516-0001 22-516-0001 22-516-0001 22-516-0001 Power Cord 22-131-0001 22-131-0001 22-131-0001 22-131-0001 Regulator Assembly 22-041-0004 22-041-0004 22-041-0005 22-041-0005 © 2018 Pinnacle Climate Technologies, Inc. Propane Forced Air Heater User’s Manual...
  • Page 12: Limited Warranty

    WHILE CONNECTED TO A POWER SOURCE LIMITED WARRANTY Pinnacle Climate Technologies, Inc. warrants this heater If Pinnacle Climate Technologies, Inc. finds the item to the original retail purchaser only, to be free from to be in normal operating condition, or not defective defects in material and workmanship for a period of one the item will be returned freight collect.
  • Page 13 DILUANTS À PEINTURE, DES PARTICULES DE POUSSIÈRE OU DES PRODUITS CHIMIQUES INCONNUS. 1 Industrial Blvd #101, Sauk Rapids, MN 56379 USA • Numéro sans frais 800 641-6996 Télécopieur : 320 251-2922 • Web : www.remingtonheater.com • Courriel : info@pinnacleclimate.com © 2018, Pinnacle Climate Technologies, Inc. RBGC-403...
  • Page 14 VÉRIFIER AVEC LE SERVICE LOCAL DES INCENDIES EN CAS DE QUESTIONS SUR L’APPLICATION. D’autres normes régissent l’utilisation des gaz combustibles et des produits de chauffage pour des utilisations spécifiques. Les autorités locales peuvent vous informer sur ces dernières. © 2018, Pinnacle Climate Technologies, Inc, Manuel de la chaufferette à air forcé au propane...
  • Page 15: Consignes De Sécurité

    MISE EN GARDE! CHAUD DURANT L’UTILISATION. NE PAS TOUCHER. GARDER HORS DE LA PORTÉE DES ENFANTS ET DES ANIMAUX ET À L’ÉCART DES VÊTEMENTS OU DE TOUT MATÉRIAU COMBUSTIBLE. © 2018, Pinnacle Climate Technologies, Inc, Manuel de la chaufferette à air forcé au propane...
  • Page 16 3. Vérifier qu’aucun article n’a été endommagé pendant le transport. Si la chaufferette est endommagée, informer immédiatement le détaillant qui vous l’a vendue. © 2018, Pinnacle Climate Technologies, Inc, Manuel de la chaufferette à air forcé au propane...
  • Page 17: Spécifications

    Protection Enveloppe Cordon intérieure électrique Contrôleur de hauteur Bouton de commande Base CONTENU DE LA BOÎTE Ensemble de tuyau Chaufferette (1) et régulateur (1) © 2018, Pinnacle Climate Technologies, Inc, Manuel de la chaufferette à air forcé au propane...
  • Page 18 Serrer fermement le robinet d’arrêt du gaz sur la – bouteille de propane après chaque utilisation. Tous les raccords doivent être protégés lorsque – démontés de la bouteille de GPL. © 2018, Pinnacle Climate Technologies, Inc, Manuel de la chaufferette à air forcé au propane...
  • Page 19 Tourner le robinet dans le sens horaire pour fermer. Robinet d’alimentation Régulateur Connecteur d’entrée Tuyau Tuyau Bouteille de propane Figure 2 Figure 3 © 2018, Pinnacle Climate Technologies, Inc, Manuel de la chaufferette à air forcé au propane...
  • Page 20: Ventilation

    2 800 cm² pour chaque sortie de 29 kWh (100 000 BTU/h). Prévoir une ouverture plus importante si plusieurs chaufferettes sont utilisées. © 2018, Pinnacle Climate Technologies, Inc, Manuel de la chaufferette à air forcé au propane...
  • Page 21: Schémas De Câblage

    ALLUMEUR BLEU ÉTINCELLES CONDENSATEUR BLEU BLANC BLEU MOTEUR BLANC NOIR BLANC NOIR FUSIBLE VERT CORDON D’ALIMENTATION CARTE DE CIRCUITS IMPRIMÉS BLEU THERMORUPTEUR TERRE (BOÎTIER) JAUNE © 2018, Pinnacle Climate Technologies, Inc, Manuel de la chaufferette à air forcé au propane...
  • Page 22: Guide De Dépannage

    2. Remplacer le robinet de endommagé. commande. 3. Accumulation de poussière 3. Nettoyer l’intérieur de la ou de débris à l’intérieur de la chaufferette. chaufferette. © 2018, Pinnacle Climate Technologies, Inc, Manuel de la chaufferette à air forcé au propane...
  • Page 23: Vue Éclatée

    Boîtier de la carte de circuits imprimés 22-506-0001 22-506-0001 22-506-0001 22-506-0001 Bouton de commande 22-516-0001 22-516-0001 22-516-0001 22-516-0001 Cordon électrique 22-131-0001 22-131-0001 22-131-0001 22-131-0001 Régulateur 22-041-0004 22-041-0004 22-041-0005 22-041-0005 © 2018, Pinnacle Climate Technologies, Inc, Manuel de la chaufferette à air forcé au propane...
  • Page 24: Garantie Limitée

    EN OUTRE, Pinnacle Climate Technologies, Inc. N’EST période de garantie, ce que Pinnacle Climate Technologies, Inc. se AUCUNEMENT RESPONSABLE ENVERS L’ACHETEUR NI réserve le droit de déterminer à sa seule discrétion.

Table of Contents