User's Manual & Operating Instructions
CONSUMER: READ AND SAVE THESE INSTRUCTIONS
GENERAL HAZARD WARNING:
DANGER
READ AND UNDERSTAND ALL OF THE INSTRUCTIONS IN THIS MANUAL
BEFORE ASSEMBLING, STARTING, OR SERVICING THE HEATER. Be sure to comply with the
instructions and warnings provided with this heater. Failure to comply can result in fire or explosion
that can cause property loss, bodily injury, or loss of life. Only persons who can follow and
understand these instructions should operate or service this heater. If you need heater info; such as
an operating manual, labels, etcetera, contact Pinnacle Products International at 800-641-6996.
NOT FOR USE IN RESIDENTIAL LIVING AREAS OR IN ENCLOSED SPACES
DANGER
WITHOUT ADEQUATE VENTILATION. FOR OUTDOOR USE. INDOOR USE
PERMITTED ONLY FOR: THE TEMPORARY HEATING OF ADEQUATELY VENTILATED
BUILDINGS OR STRUCTURES UNDER CONSTRUCTION, ALTERATION OR REPAIR. This is
an unvented portable heater that uses air (Oxygen) from within the area in which it is used. Failure
to provide adequate combustion and ventilation air will result in asphyxiation, carbon monoxide
poisoning, bodily injury or death. Refer to "Ventilation" on Page 6.
Fax: (215)-891-8461
Model Numbers
MH-70-SS-A
© 2014 Pinnacle Products International, Inc.
668 Stony Hill Road #302 Yardley, PA 19067 USA
• Web: www.masterindustrialproducts.com • Email: info@pinnacleint.com
751000241-14

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Master MH-70-SS-A and is the answer not in the manual?

Questions and answers

Summary of Contents for Pinnacle Master MH-70-SS-A

  • Page 1 Only persons who can follow and understand these instructions should operate or service this heater. If you need heater info; such as an operating manual, labels, etcetera, contact Pinnacle Products International at 800-641-6996. NOT FOR USE IN RESIDENTIAL LIVING AREAS OR IN ENCLOSED SPACES DANGER WITHOUT ADEQUATE VENTILATION.
  • Page 2: Table Of Contents

    THE INSTALLATION OF THIS HEATER SHALL COMPLY WITH THE REGULATIONS OF THE AUTHORITIES HAVING JURISDICTION. Look for this icon throughout the manual for helpful tips on how to assemble, use and clean your OFR Heater. © 2014, Pinnacle Products International, Inc. Oil Fired Radiant Heater User’s Manual...
  • Page 3: Safety Information

    100,000 Btu / Hr heater rating. Refer to accordance with the thermostat setting. “Ventilation” on page 5 for further instructions. © 2014, Pinnacle Products International, Inc. Oil Fired Radiant Heater User’s Manual...
  • Page 4: Features And Specifications

    Fuel Consumption: G/Hr Fuel Tank Capacity: G Max Operating Hours Volts: AC/Hz 120V / 60Hz Amps Heating Area m 1,750 Specifications subject to change without notice. Features MH-70-SS-A Figure 1 © 2014, Pinnacle Products International, Inc. Oil Fired Radiant Heater User’s Manual...
  • Page 5: Mh-70-Ss-A Assembly

    Figure 2. Attach the handle while still in the box 2. Insert screws and tighten firmly. for easier unpacking. (See Figure 3) Figure 2 Figure 3 © 2014, Pinnacle Products International, Inc. Oil Fired Radiant Heater User’s Manual...
  • Page 6 Remove existing screws from shell ring on either side of heater. Step 2: Line up holes on heat shield with holes in shell ring. Attach with screws removed in step 1. Heat Shield © 2014, Pinnacle Products International, Inc. Oil Fired Radiant Heater User’s Manual...
  • Page 7: Ventilation

    PROPERLY IN THIS HEATER. NOTE: Kerosene should only be stored in a blue container that is clearly marked “Kerosene.” Never store Kerosene in a red container. Red is associated with gasoline. © 2014, Pinnacle Products International, Inc. Oil Fired Radiant Heater User’s Manual...
  • Page 8 2. Push the power switch to the “ON” position. The power indicator lamp will light and heater will ignite. (See Figure 5) Power Switch Electrical Outlet Figure 6 Figure 5 © 2014, Pinnacle Products International, Inc. Oil Fired Radiant Heater User’s Manual...
  • Page 9: Maintenance

    TIP: Follow the long term storage instructions to flush the tank. Flush tank every 200 hours of operation or as needed. DO NOT flush with water, use fresh Kerosene only. © 2014, Pinnacle Products International, Inc. Oil Fired Radiant Heater User’s Manual...
  • Page 10 Use a cotton swab and water or alcohol to clean the lens of the photocell. Be certain to reinstall the photocell in proper position as shown below. (See Figure 10) Figure 10 © 2014, Pinnacle Products International, Inc. Oil Fired Radiant Heater User’s Manual...
  • Page 11: Troubleshooting Guide

    1. Be sure pump pressure is adjusted correctly. Poor combustion and / or soot 2. Poor fuel quality. 2. Be sure Kerosene/ diesel is not old production. or contaminated. © 2014, Pinnacle Products International, Inc. Oil Fired Radiant Heater User’s Manual...
  • Page 12: Wiring Diagram

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Wiring Diagram MH-70-SS-A AC 120V/60Hz AC 125V 3.15A ELECTRIC OUTLET Figure 12 © 2014, Pinnacle Products International, Inc. Oil Fired Radiant Heater User’s Manual...
  • Page 13: Exploded View

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Exploded View MH-70-SS-A Figure 13 © 2014, Pinnacle Products International, Inc. Oil Fired Radiant Heater User’s Manual...
  • Page 14: Parts List

    Photocell Assembly 75-038-0200 Back Cover 75-013-0105 Power Supply Cable Assembly 75-032-0186 Electrical Outlet Assembly 75-029-0100 Return Pipe 75-055-0100 Return Hose 75-055-0200 Electronic Pump Bracket 75-027-0255 Heat Shield 75-012-0320 © 2014, Pinnacle Products International, Inc. Oil Fired Radiant Heater User’s Manual...
  • Page 15: Warranty

    WHILE CONNECTED TO A POWER SOURCE LIMITED WARRANTY Pinnacle Products International, Inc. warrants this heater If Pinnacle Products International, Inc. finds the item to to the original retail purchaser only, to be free from defects be in normal operating condition, or not defective the item in material and workmanship for a period of one (1) year will be returned freight collect.
  • Page 16 © 2014 Pinnacle Products International, Inc. 668 Stony Hill Road #302 Yardley, PA 19067 USA • Toll Free (800)-641-6996 Fax: (215)-891-8461 • Web: www.pinnacleint.com • Email: info@pinnacleint.com...