5
7 Acquisition of other data on the panel • • • [QIP]
The command QIP is for acquiring data other than those available with QS1 (data necessary before turning the power on)
and QS2 (data to inform of operational status change).
Command
Effective Operation
Format
Modes
[QIP]
All operations
Data Arrangement
ECO
1
SERIAL
2
HOUR METER
3
BACKUP HR MTR
4
PON COUNTER
CS
Note : The real product serial number is displayed in "SERIAL".
7 Acquisition of panel adjustment data (common data) • • • [QAJ]
The command QAJ is for acquiring data on the panel's factory-preset items that are common to the main unit and that
share the same memory.
Command
Effective Operation
Format
Modes
[QAJ]
All operations
Data Arrangement
ECO
1
V-SUS adjustment value
2
V-OFT adjustment value
3
V-RST-P adjustment value
4
XSB adjustment value
5
YSB adjustment value
6
YTG adjustment value
7
YTW adjustment value
8
RSW adjustment value
9
R-RIVISE setting value
10
G-RIVISE setting value
11
B-RIVISE setting value
CS
5
6
Function
To acquire data on operations of the panel Return data: 3 (ECO)+39(DATA)+2(CS)=44Byte
Data
Output Example
Length
3Byte
QIP
15Byte
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _
8Byte
00000000
8Byte
00000000
8Byte
00000000
2Byte
94
Function
To acquire data on operations of the panel Return data: 3 (ECO)+27(DATA)+2(CS)=32Byte
Data
Length Output Example
3Byte
QAJ
3Byte
128
3Byte
128
3Byte
128
3Byte
128
3Byte
128
3Byte
128
3Byte
128
3Byte
128
1Byte
0
1Byte
0
1Byte
0
2Byte
B7