ABB HT570679 Operation Manual page 62

Table of Contents

Advertisement

Operation Manual / 4 Product description / A150-M.. - A155-M..
4
Monitoring operation
4.3.5
Replacing the speed sensor
Hot speed sensor
Danger of burns. The speed sensor can reach temperatures of more than
100 °C during operation.
WARNING
Wear safety gloves when disassembling the speed sensor.
Wear safety gloves to protect against thermal hazards.
The speed sensor supplied by ABB is equipped with a sealing lip and an O-ring. No additional
gasket is required during assembly.
Figure 18: Replacing the speed sensor
Part number
86505
Table 8: Tightening torque (86505)
Reduce the engine performance to idling and then stop the engine. Pay attention to post-
lubrication (Stopping the engine [➙ 40]).
Switch off the lubricating oil supply to the turbocharger.
Disconnect cable connector (86515) from speed sensor (86505).
Unscrew and remove defective speed sensor (86505).
Screw in new speed sensor (86505) as far as it will go and tighten.
Connect cable connector (86515) to speed sensor (86505).
Switch on lubricating oil supply to the turbocharger.
© Copyright 2017 ABB. All rights reserved.
A150
M12 x 1.5
15 Nm
HZTL4032_EN
Page 32 / 120
A155
M12 x 1.5
15 Nm
Revision F
January 2017

Advertisement

Table of Contents
loading

This manual is also suitable for:

A155-m seriesA150-m67A150-m series