Setting The Clock; Setting The Maximum Floor Temperature - Veria Control ET45 Installation Manual

Table of Contents

Advertisement

EN

SETTING THE CLOCK

With the thermostat turned on.
Press "
Use the Up/Down key to select the hours.
Press "
Use the Up/Down key to select the minutes.
Press "
Use the Up/Down key to select the day of the week.
After setting week day do not press any further buttons and the
thermostat will go back to normal operating mode mode.
SETTING THE FLOOR TEMPERATURE MAX. LIMIT
This function is used for wooden floors mainly and is only available
in program modes using the floor sensor (program mode 3 and 5)
The temperature setting should be maximum 35C, which is also the
default set point of the thermostat.
If you choose to control the floor temperature solely by the floor
sensor (program mode 2) the max. floor temperature is set for 35C
and can't be changed.
Change the floor temperature max. limit (program mode
3 and 5)
With the thermostat turned off.
Hold the "M" button for 10 seconds until the display shows "
Now let go of the button "M" and the display will show "SET".
You are now prompted to enter the maximum floor temperature
(temperature range 20°C-45°C)
8
" once, hour will be flash.
" again, minute will be flash.
" button again, till the week day flashes.
Basic functionality
".

Advertisement

Table of Contents
loading

This manual is also suitable for:

Control t45

Table of Contents