  • Page 1 Veria Control T45 Installation guide Installationsanleitung Installasjonsveiledning Installationsguide Asennusopas Installationsvejledning...
  • Page 2: Table Of Contents

    Table of content Introduction Introduction Veria Control T45 is an advanced digital timer thermostat, which allows you to control your floor heating system by either the floor Button and display description temperature, the room temperature or combined. Installing and wiring the thermostat Please follow the instructions in this manual to ensure many years of trouble free usage. Basic functionality - Select how to control your Congratulations with your new Veria floor heating system..floor heating system 6 - Recommended settings...
  • Page 3: Button And Display Description

    Button and display description Installing and wiring the thermostat To mount the thermostat to the wall box/wall socket, first open the Current floor temperature thermostat by gently pushing the tabs in the buttom of the thermo- Current room temperature stat. To fix the thermostat, screw in properly sized screws into the Frost protection mode activated wall socket/wall box. Thermostat on When proberly fastend and cables connected (see diagram below), Day of the week mount the frontpanel to the backpart again. Timer mode activated Electrical wall box/socket Wiring diagram 85-240V~ Max On/off Mode Down Heating element Remote sensor Clock warming...
  • Page 4: Basic Functionality

    Basic functionality Basic functionality POWER ON/OFF RECOMMENDED SETTINGS To turn thermostat on or off press “ ” Veria recommends the following settings for different type of floor constructions: SELECT HOW TO CONTROL YOUR FLOOR HEATING SYSTEM Your Veria floor heating system can be controlled either by the: Top flooring Wooden Tiled • Floor temperature - program mode 2 Program mode floor* floor** The heating element turns on/off around a floor temperature setpoint (the temperature shown in the display is the actual (room sensor) floor temperature) If total effect: 0W-1840W •...
  • Page 5: Setting The Clock

    Basic functionality Basic functionality SETTING THE CLOCK READING THE FLOOR TEMPERATURE (only in program mode 3 With the thermostat turned on. and 5) Press “ ” once, hour will be flash. With the thermostat turned on. Use the Up/Down key to select the hours. Press “M” once, the “ FT ” will be flashed, and the display will Press “ ” again, minute will be flash. show the floor temperature. Use the Up/Down key to select the minutes. Press “ ” button again, till the week day flashes. In program mode 2 (floor sensor) the display always shows the current Use the Up/Down key to select the day of the week. floor temperature. After setting week day do not press any further buttons and the thermostat will go back to normal operating mode mode.
  • Page 6: Timer Functionality

    Timer functionality Timer functionality ACTIVATE TIMER MODE Example, weekdays: When using the timer mode, you must first activate the timer mode: Period 1 starting at 07.00 - Temperature setting 22C Period 2 starting at 08.30 - Temperature setting 18C With the thermostat turned on, hold the “M” button for 3 seconds. Period 3 staring at 17.00 - Temperature setting 22C You can select below settings: Period 4 starting at 23.00 - Temperature setting 18C 00 = Override (disable timer functionality) Example, weekend: 01 = Programmable. And the display will show “ ”. Period 1 staring at 09.00 - Temperature setting 22C Period 2 staring at 23.00 - Temperature setting 18C Leave the thermostat and it will go back to normal displaying. Period 3 staring at 23.01 - Temperature setting 22C Period 4 staring at 23.02 - Temperature setting 18C PROGRAMMING THE TIMER - Mode 01 When programming you need to select Programmable function and My settings: the display must show “ ” (see above) Week days: You can now set the heating programs. The thermostat must have Period 1 on °C 4 heating periods for the weekdays and 4 heating periods for the...
  • Page 7 Timer functionality Notes How to progamme the timer: Hold the “ ” for 3 seconds, the number 1 and “Mo Tu We Th Fr” are displayed. This indicates that you can program the first switching time for the week-day. Use Up/Down key to set the required start time. Press “ ” to accept this setting. Use the Up/Down key to set the required temp. Press “ ” to accept this setting. Repeat for switching times 2-4 week-day. After you have programmed times 1-4 for the weekday, you are now able to set the switching times for weekend “Sa Su” will be displayed. Use Up/Down key to set the required start time. Press “ ” to accept this setting. Use the Up/Down key to set the required temp. Repeat for switching times 2-4 for the weekend. To disable the timer, select “Override” (Mode 01) How to override settings in TIMER MODE At any time you can change the preset timer temperature settings by pressing the Up/Down key. Your manual override will apply until the start of the next timer cycle.
  • Page 8: Technical Specifications

    Technical specifications Veria warranty Warranty certificate External sensor: NTC 10 kOhm at 25° C Sensor values: Name: 15°C 14,8 kOhm Address: 18°C 13,1 kOhm 20°C 12,1 kOhm Zip code/City: 22°C 11,2 kOhm Telephone: Display: Please notice! Power consumption: <2W In order to obtain the Veria warranty an authorized electrician/ Set-point range: Room: 5°C to 35°C installer must fill in the below fields. Floor: 20°C to 35/45°C Accuracy: ±1°C Electrician/installer: Installation date: Buttons:...