GE Tetra GEPS24-100U-GLX2 Installation Manual page 3

Led systems power supply 120-277 vac input/24vdc output/100w

Advertisement

Tetra
Power Supply GEPS24-100U-GLX2
®
Power Supply Specifications
Performance Data
Input Voltage (VAC)
Input Frequency (Hz)
Input Current (A)
THD**
PF**
Output Voltage (VDC)
Output Current (ADC)
Output Power (W)
Environmental Operating Temperature Range
Environmental Humidity (non-condensing)
Environmental Storage Temperature Range
Environmental Rating
Dimensions
*Maximum case temperature is 85°C
**At 120VAC - 277VAC Full Load
Troubleshooting
Symptom
Solution
All LEDs are OFF
• The GEPS24-100U-GLX2 features a new built in output overload shutdown feature that automatically resets when the
AC supply is removed and reapplied. So if all letters are off, first verify whether or not the output can be reset by first
switching off then switching back on the AC supply. If the letters do not re-light, then proceed to the following solutions.
• Check AC input connection and/or check circuit breaker
• Check wire connection(s) at the Tetra® LED System and power supply for improper termination(s) or short circuits.
Properly terminate or replace the wire connection(s).
• Check that connections are the red striped wire (+) of the LED strip to the red wire (+) of the power supply and the white
wire (-) of the LED strip to the black or blue wire (-) of the power supply.
• Ensure the overall length of the Tetra® LED System does not exceed the maximum load. If so, remove the excess load and
cycle the AC supply to reset the drivers built in overload protection.
Some LEDs appear dim
• Ensure the length of supply wire is equal to or below the recommended remote mounting distance.
Some of the LEDs
• Check wire connection(s) at the Tetra® LED System and power supply for improper termination(s) or short circuits.
are not illuminated
Properly terminate or replace the wire connection(s).
• Check that connections are the red striped wire (+) of the LED strip to the red wire (+) of the power supply and the white
wire (-) of the LED strip to the black or blue wire (-) of the power supply
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to
cause harmful interference in which case the user will be required to correct the interference at his own expense.
This Class [A] RFLD complies with the Canadian standard ICES-005. Ce DEFR de la classe [A] est conforme à la NMB-005 du Canada.
This product is intended to be used as a lamp control gear that is installed after the mains control switch.
Min
108
0.35
0.9
24.0
-40°C
0%
-40°C
IP66 rated: must be protected from direct exposure to the weather
9.5 in. x 1.7 in. x 1.2 in. (240 mm x 43 mm x 30 mm)
Conforms to the following standards:
www.gecurrent.com
© 2021 Current Lighting Solutions, LLC. All rights reserved. GE and the GE monogram are trademarks of the
General Electric Company and are used under license. Information provided is subject to change without
notice. All values are design or typical values when measured under laboratory conditions.
SIGN287 (Rev 07/13/21) DOC-2000006
Installation Guide
Nominal
120-277
50/60
24.5
+25°C
+60°C*
Max
305
1.1
20
25.0
4.0
96
95%
+85°C