Mitsubishi Electric MUZ-LN VG Series Service Manual page 24

Indoor unit
Hide thumbs Also See for MUZ-LN VG Series:
Table of Contents

Advertisement

ABSENCE DETECTION ( )
This function automatically changes the operation to No occupancy energy-saving mode or No occupancy Auto-OFF mode
when nobody is in the room.
(1) To activate this No occupancy energy-saving mode, press SENSOR button until
of the remote controller.
(2) To activate this No occupancy Auto-OFF mode,
the remote controller.
(3) Press SENSOR button again to cancel the ABSENCE DETECTION.
No
occupancy
detected
About
10 min.
Normal
Energy-
saving
mode
Normal
Auto-OFF
mode
• Even if the unit is turned OFF due to No occupancy Auto-OFF mode, the display of the remote controller remains to indicate the
unit is in operation. Press STOP/OPERATE(OFF/ON) button then press STOP/OPERATE(OFF/ON) button again to restart operation.
• When OFF timer is set, a priority is given to OFF timer.
• No occupancy energy saving mode or No occupancy Auto-OFF mode are not available during POWERFUL operation.
• The unit will not be turned off if no one is detected during normal operation mode, even though No occupancy Auto-OFF mode
is activated.
9-10. AIRFLOW CONTROL MODE
AIRFLOW CONTROL mode offers air conditioning according to a location of an occupant in a room detected by i-see SENSOR.
(1) Press DIRECTION button during COOL, DRY, HEAT or AUTO mode to activate the AIRFLOW CONTROL mode.
This mode is only available when the i-see control mode is effective.
(2) Each press of DIRECTION button changes AIRFLOW CONTROL in the following order:
(INDIRECT)
(DIRECT)
(INDIRECT) : An occupant will be less exposed to direct airflow.
(DIRECT) : Mainly the vicinity of an occupant will be air-conditioned.
(EVEN) : The unit learns the area where an occupant spend most of the time, and evens out the temperature
of that area.
NOTE:
• Horizontal and vertical airflow directions will be automatically selected.
• When more than a couple of people are in a room, the AIRFLOW CONTROL mode may work less effectively.
• If you still feel uncomfortable with the air direction determined by the INDIRECT mode, adjust the air direction manually.
(3) Cancelling the i-see control mode automatically cancels the AIRFLOW CONTROL mode.
• The AIRFLOW CONTROL mode is also cancelled when the VANE CONTROL or WIDE VANE buttons is pressed.
OBH766C
Cancel
Occupancy
detected
About 1 HR.
Saving energy
Saving more
Saving energy
Turn OFF
(EVEN)
(OFF)
press SENSOR button until
Normal
24
appears on the operation display
appears on the operation display of