Advertisement

Quick Links

INSTRUCTION MANUAL
TAMPING RAMMER
EMR70H
To reduce the risk of injury, all operators and maintenance personnel must read and understand these
instructions before operating, changing accessories, or performing maintenance on Masalta power
equipment. All possible situations cannot be covered in these instructions. Care must be exercised
by everyone using, Maintaining or working near this equipment.
!
WARNING
R

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EMR70H and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Masalta EMR70H

  • Page 1 To reduce the risk of injury, all operators and maintenance personnel must read and understand these instructions before operating, changing accessories, or performing maintenance on Masalta power equipment. All possible situations cannot be covered in these instructions. Care must be exercised...
  • Page 2: Table Of Contents

    Contents Introduction…………………………………………………..……………………………………………1 Application ………………………………………………………………………………………..……….2 Operating safety……………………………………………………………………………………..… 2-4 Label locations…………………………………………………………………………………………….4 Safety and Operating Labels …………………………………………………………………….5-6 Prior to Starting the Operation ………………………………………………………………………..6-7 Operation ………………………………………………………………………………………………… 7-8 Service and Maintenance ………………………………..…………………………………………… 8-9 Specification ………………………………………………..………………………………………………9 Transportation ………………………………………………….………………………………………….10 Trouble shooting ……………………………………………….……………………..……………….10-11 Warranty and Maintenance Record ………………………………………….……………………….. 12 Introduction Thanks for your selection of this equipment.
  • Page 3: Application

    NEVER touch hot muffler, engine cylinders, or cooling fins. Burns will result. NEVER use accessories or attachments which are not recommended by MASALTA for rammer. Damage to rammer and/or injury to user may result. NEVER leave a running machine unattended.
  • Page 4 NEVER run machine indoors or in an enclosed area such as a deep trench unless adequate ventilation is provided. Exhaust gas from the engine contains poisonous carbon monoxide gas; exposure to carbon monoxide can cause loss of consciousness and may lead to death. NEVER tamper with or disable the function of operating controls.
  • Page 5: Label Locations

    ALWAYS replace worn or damaged components operating rammer. with spare parts designed and recommended by DO NOT alter engine speeds. Run engine MASALTA for servicing this rammer. only at speeds specified in Technical Data Section. Label Location...
  • Page 6: Safety And Operating Labels

    Safety and Operating Labels MASALTA machines use international pictorial labels where needed. These labels are described below: Label Meaning DANGER! Engines emit carbon monoxide; operate only in well-ventilate area. Read the Operator’s Manual for machine information. No sparks, flames, or burning objects near the machine.
  • Page 7: Prior To Starting The Operation

    Label Meaning CAUTION! For optimal control, performance, and minimal hand/arm vibration, grasp handle as shown. WARNING! Serious injury if struck by compressed spring or cover. If the spring system cover is removed improperly, the springs can eject. Guaranteed sound power level in dB(A). NOTICE! Throttle control lever: Turtle = Idle or Slow...
  • Page 8: Operation

    Check every bolt, nut or screwed area for tightness. Loosened due to vibration may result in unexpectedly serious trouble. Be sure to tighten any screwed area. Remove dirt and dust. Particularly clean the vicinity of recoil starter and foot. Operation Starting up for Petrol engine 1.
  • Page 9: Service And Maintenance

    Note: If engine performance is poor, check, clean, and replace air filter elements as needed. Air Cleaner Cleaning for EMR70H (6 to 12 months Service): Remove element from pre-cleaner at the top of crank case and clean it with cleaning oil (kerosene).
  • Page 10: Specification

    Clean exterior with a cloth soaked in clean oil. Store unit covered with plastic sheet in moisture free and dust free location out of direct sunlight. Specification Model EMR70H Motor Honda GX160 Power kW (hp) 4.0 (5.5)
  • Page 11: Transportation

    Transportation 1. Shutdown engine for transportation. 2. For transportation, tighten fuel tank cap securely and close fuel cock to prevent fuel from spilling. 3. Drain fuel for transportation over long distance or bad road. 4. Secure machine firmly to prevent it from moving or tipping. 5.
  • Page 12 B. Engine Troubleshooting Guide SYMPTOM POSSIBLE CAUSE SOLUTION Difficult to start Ignition plug being bridging? Check ignition system. Fuel is available but spark Carbon deposit at ignition? Clean or replace ignition. plug will not ignite.(Power available at high tension Short circuit due to deficient insulator? Replace insulators.
  • Page 13: Warranty And Maintenance Record

    WARRANTY WARRANTY WARRANTY WARRANTY These products are covered by warranty for a period of six (6) months from the date of purchase against defects in material or workmanship provided that: · The product concerned has been operated and maintained in accordance with the operating instructions. ·...
  • Page 14 Distributed By MASALTA ENGINEERING CO., LTD Add: 20 Dalian Road, Baohe Industrial Estate, Hefei, China Tel: 86-551-64846601, 64846580 Fax: 86-551-64846616, 64846626 E-mail: sales@masalta.com.cn, masalta@mail.hf.ah.cn Http://www.masalta.com.cn Version: 01/14/01...