Cleaning the drain pump
Note: Please read the information in
the "Safety" → Page 4 and "Prevent-
ing material damage" → Page 11 sec-
tions to ensure that you use the appli-
ance safely.
Requirement: "The drain pump is
empty." → Page 47
Since water may remain in the
1.
drain pump, remove the pump cap
carefully.
The filter insert in the pump
housing may become stuck due
to coarse particles of dirt.
Loosen the dirt and remove the
filter insert.
Clean the interior, the thread on
2.
the pump cap and the pump hous-
ing.
Cleaning and servicing en
The pump cap is comprised of two
parts which can be taken apart for
cleaning.
Make sure that the impeller in the
3.
drain pump can be rotated.
Insert the pump cap.
4.
Ensure that the parts of the
pump cap are correctly as-
sembled.
Screw on the pump cap.
5.
90°
The handle on the pump cap must
be in a vertical position.