  • Page 1 HeartSine samaritan ® SAM 350P Trainer model TRN-350-1 User Manual...
  • Page 2 This User Manual provides instructions on how to operate the HeartSine samaritan PAD 350P Trainer. The HeartSine samaritan PAD 350P Trainer is a non-medical device intended to be used for the training of emergency responders in the proper use of the HeartSine samaritan PAD 350P automated external defibrillator. The Trainer has no therapeutic capabilities and must not be used in real life rescue situations.
  • Page 3 Do not press any buttons whilst inserting the Remote Control batteries as this will reset the Remote Control ID. 4) Press the On/Off button on the HeartSine samaritan PAD 350P Trainer and listen to the voice prompts to ensure that the unit is functioning.
  • Page 4: On/Off Button

    The action arrows around this icon will preparing to deliver a shock. flash to instruct the user that the HeartSine samaritan PAD 350P pads should be Status indicator attached to the patient as indicated.
  • Page 5 B Coil Handle 4) Place the pads on top of the Trainer-Pak cartridge, ensuring that the wires are beneath the pads. 5) Close the Trainer-Pak cartridge by sliding the yellow tray into place. HeartSine samaritan PAD 350P Trainer User Manual...
  • Page 6: The Remote Control

    G Select Scenario H Attach Electrode Pads Turning off the Trainer The Remote Control can be used to turn off the HeartSine samaritan PAD 350P Trainer. To turn the Trainer off press the red button on the Remote Control. Changing the Volume There are four volume settings available on the HeartSine samaritan PAD 350P Trainer.
  • Page 7 Preprogrammed Training Scenarios The HeartSine samaritan PAD 350P Trainer has six preprogrammed training scenarios to choose from. All preprogrammed scenarios are based on AHA/ERC 2015 guidelines. Details of the scenarios are given below. Scenario 1 1. Setup mode “Call for Medical assistance”, “Pull green tab”, etc 2.
  • Page 8 User to apply CPR with advisory as required; this includes an audible indication of when to perform rescue breaths - the metronome changes from a “beep” to a “tick” for the duration of ten compressions. 9. Repeat Steps 6 to 8 repeated until ‘On/Off’ button is pressed heartsine.com...
  • Page 9 Manual Control of the HeartSine samaritan PAD 350P Trainer The Remote Control allows Training providers to control the scenario manually. When turned on the HeartSine samaritan PAD 350P Trainer will operate as detailed in the training scenarios listed. Training providers can override this by pressing the ‘Shock required’, ‘No Shock required’...
  • Page 10: Maintenance

    “Warning. Low battery” If this warning is heard you may continue to use your HeartSine samaritan PAD 350P Trainer for a limited period of time. If the battery becomes completely depleted the Trainer device will shut itself down. At this point the Trainer should be recharged.
  • Page 11: Remote Control Batteries

    Pairing a Remote Control with the HeartSine samaritan PAD 350P Trainer Each HeartSine samaritan PAD 350P Trainer has a specific Remote Control to operate it. This is to allow multiple devices to be used in close vicinity without interference. In the unlikely event that your Remote Control no longer operates with your Trainer it may need to be paired with your Trainer again.
  • Page 12 CPR providers. HeartSine recommend that all potential users of the HeartSine samaritan PAD 350P are trained by a competent training organization in both the use of CPR and HeartSine samaritan PAD 350P, prior to placing a HeartSine samaritan PAD 350P into service. Should the Guidelines change, software will be available to upgrade the HeartSine samaritan PAD 350P to comply.
  • Page 13: Disposal Instructions

    If you wish to dispose of the HeartSine samaritan PAD 350P Trainer unit, it should be disposed of at an appropriate recycling facility according to national, state and local requirements. Alternatively return the unit to your local distributor or HeartSine Technologies for disposal.
  • Page 14 Notes heartsine.com...