5 Monitoring during operation / 5.2 Turbocharger speed
5.2.4
Replacing the speed sensor
WARNING
Hot cable connector and hot speed sensor
Danger of burns. The cable connector and speed sensor can reach temperat-
ures in excess of 100 °C during operation.
When disassembling the cable connector and speed sensor, wear safety
u
gloves.
Wear safety gloves to protect against thermal hazards.
Reduce the engine performance to idling and then stop the engine. Pay attention to post-
u
lubrication
(Stopping the engine
Switch off the lubricating oil supply to the turbocharger.
u
Disconnect the cable connector from the speed sensor.
u
Screw out defective speed sensor.
u
Screw in new speed sensor to the stop.
u
The speed sensor is designed with a sealing lip and does not require any additional gasket
for assembly.
Connect cable connector (86515) with the speed sensor (86505)
u
Switch on lubricating oil supply to the turbocharger.
u
5.2.5
Malfunction of the speed measurement system
The possible reasons for malfunction of the speed measurement system are described in
chapter Troubleshooting (Reasons for malfunction of the speed sensor).