Sanyo PLC-XM80 Owner's Manual page 88

Table of Contents

Advertisement

Appendix
Status Read Command
Format
The command is sent from PC to the projector with the
format below;
'CR' [Command] 'CR'
Command: one character (refer to the command table
below.
The projector decodes the command and returns the
'Character string' with the format below;
Command
CR0
CR6
The tables on page 87 and 88 show the typical command lists for controlling the projector. Please consult your local dealer
for further information of other commands.
88
Projector
Function
Return
Status Read
Temperature Read
S1 S2 S3
Power On
00
Stand-by mode
80
Countdown
40
Cooling down
20
Power Malfunction
10
Cooling down at the temperature anomaly
28
Cooling down at Power Management mode
24
Power Management mode after Cooling down
04
Cooling down after the projector is turned off when the lamps
21
are out.
Stand-by mode after Cooling down when the lamps are out.
81
Stand-by mode after Cooling down at the temperature
88
anomaly.
S1 = Temperature at Sensor 1 (˚C)
S2 = Temperature at Sensor 2 (˚C)
S3 = Temperature at Sensor 3 (˚C)
(ex.) S1 = 12.3˚C��� S2 = 23.4˚C��� S3 = 34.5˚C
��� S2 = 23.4˚C��� S3 = 34.5˚C
S2 = 23.4˚C��� S3 = 34.5˚C
--> The projector displays "12.3 23.4 34.5"
( For each sensor, two digit and the tenth place numbers are
displayed with a space between each temperature.)
Communication failure
?
Projector status

Advertisement

Table of Contents
loading

This manual is also suitable for:

Plc-xm80l

Table of Contents