3.2.6 Capacitance
range
Resolution Accuracy
4nF
0.001nF
40nF
0.01nF
400nF
0.1nF
4µF
0.001µF
40µF
0.01µF
400µF
0.1µF
4mF
0.001mF
40mF
0.01mF
- Overload protection: 250V DC or AC (RMS)
3.2.7 Diode Test
range
Resolution Function
0.001V
approx.
- Forward DC current :
-
Revers DC voltage: approx. 3.2V
- Overload protection:250V DC/AC(rms)
Continuity
3.2.8
range
Resolution Function
0.1Ω
- Open circuit voltage: approx. 1.0V
- Overload protection:250V DC/AC(rms)
±(4.0% reading + 5 digits)
±(3.0% reading + 3 digits)
±(4.0% reading + 5 digits)
Shows approximate forward
voltage of diode
1mA
If measured resistance is
less than 50Ω, a buzzer will
sound
11
3.2.9 Frequency
3.2.9.1 Frequency (V position):
range
Resolution Accuracy
40Hz
0.01Hz
400Hz
0.1Hz
4kHz
0.001kHz
10kHz
0.01kHz
-
Range 10Hz~10kHz
:
-
Input Voltage
: >
0.2V AC (Input voltage should increase
along with the frequency)
3.2.9.2 Frequency (Hz position):
range
Resolution Accuracy
40Hz
0.01Hz
400Hz
0.1Hz
4kHz
0.001kHz
40kHz
0.01Hz
400kHz
0.1kHz
4MHz
1kHz
40MHz
10kHz
- Overload protection:250V DC/AC(rms)
- Input Voltage:3V peak to peak AC
3.2.9.3 Duty Cycle
range
Resolution Accuracy
1 -99%
%
0.1%
±(1.5% reading + 5 digits)
±(1.5% reading + 5 digits)
±(1.5% reading + 5 digits)
±2.0%
12