Electromagnetic Immunity; Reliability - Annualized Failure Rate; Warranty - Seagate ST500VM000 Product Manual

Video 3.5 hdd
Table of Contents

Advertisement

www.seagate.com

2.11 Electromagnetic immunity

When properly installed in a representative host system, the drive operates without errors or degradation in performance
when subjected to the radio frequency (RF) environments defined in the following table:
Table 4 Radio frequency environments
Test
Electrostatic discharge
Radiated RF immunity
Electrical fast transient
Surge immunity
Conducted RF immunity
Voltage dips, interrupts

2.12 Reliability - Annualized Failure Rate

The product will achieve an Annualized Failure Rate (AFR) of 0.55% when operated in an environment of ambient air
temperatures of 25°C. Operation at temperatures outside the specifications shown in
product AFR. AFR is a population statistics that is not relevant to individual units.
• AFR specifications are based on the following assumptions for consumer electronics environments:
• 8760 power-on-hours per year
• 10,000 average motor start/stop cycles per year
• Operations at nominal voltages
• Temperatures outside the specifications in
• Normal I/O duty cycle for consumer electronics environments. Operation at excessive I/O duty cycle may degrade
product reliability.
The consumer electronics environment of power-on-hours, temperature, and I/O duty cycle affect the product AFR. The
AFR will be degraded if used in an enterprise application.

2.13 Warranty

To determine the warranty for a specific drive, use a web browser to access the following web page:
http://www.seagate.com/support/warranty-and-replacements/
From this page, click on "Is my Drive under Warranty". Users will be asked to provide the drive serial number, model
number (or part number) and country of purchase. The system will display the warranty information for the drive.
Seagate Video 3.5 HDD Product Manual, Rev. B
Description
Contact, HCP, VCP: ± 4 kV; Air: ± 8 kV
80MHz to 1,000MHz, 3 V/m,
80% AM with 1kHz sine
900MHz, 3 V/m, 50% pulse modulation @ 200Hz
± 1 kV on AC mains, ± 0.5 kV on external I/O
± 1 kV differential, ± 2 kV common, AC mains
150kHz to 80MHz, 3 Vrms, 80% AM with 1kHz sine
0% open, 5 seconds
0% short, 5 seconds
40%, 0.10 seconds
70%, 0.01 seconds
Section 2.9
Performance
may reduce the product reliability.
Reference
Level
standard
B
EN61000-4-2: 95
EN61000-4-3: 96
A
ENV 50204: 95
B
EN61000-4-4: 95
B
EN61000-4-5: 95
A
EN61000-4-6: 97
C
C
EN61000-4-11: 94
C
B
Section 2.9
may increase the
17

Advertisement

Table of Contents
loading

This manual is also suitable for:

St1000vm002