UT-4579 X-Band Up Converter
Specifications
2.2.9
Transfer
2.2.9.1
Gain
35 dB ±2 dB
2.2.9.2
Attenuation Adjustment
• STANDARD: 0 to 25 in 0.25 dB steps
• OPTIONAL: 0 to 25 in 0.1 dB steps
2.2.9.3
Gain Stability
± 0.25 dB/day
2.2.9.4
Ripple
Contact Comtech EF Data Product Support for your specific requirements.
• ±0.25 dB (±18 MHz) – OPTIONAL ±20 MHz
• 0.75 dB (±36 MHz) – OPTIONAL ±40 MHz
2.2.9.5
Slope
0.05 dB/MHz
2.2.9.6
IF Bandwidth
Contact Comtech EF Data Product Support for your specific requirements.
• STANDARD:
• OPTIONAL:
36 or 72 MHZ
40 or 80 MHz