In the image below, the scanned image is misaligned in the center. The arrow shows the feed direction
of the original.
1. Press the
home button, if necessary.
2. Select Settings > General Settings > Scan Settings > Scan Options > Image Stitching
Adjustment.
You see a screen like this:
3. Tap the adjustment value area to adjust the value directly, or use the +/- buttons to change the
value.
Shifting the value of the adjustment by 1 will correct the misalignment by approximately 0.1 mm.