Inspecting Burners - EmberGlow DE18DBNGR/LPR Owner's Operation And Installation Manual

Table of Contents

Advertisement

LIGHTING INSTRUCTION
Continued
9. Slightly push in and turn control knob counterclockwise
to the ON position.
10.To leave pilot lit and shut off burners only:
Turn control knob clockwise
position, or set selector switch in the OFF position.
TO TURN OFF GAS
TO APPLIANCE
Shutting Off Appliance
1. Slightly push in and turn control knob clockwise
to the OFF position.
2. Close equipment shutoff valve.
CURING
THE LOGS
During the 2-3 hour appliance break-in period, you may
detect an odor from the appliance as the various paints
and compounds used in the manufacturing of this log
set cure.
Check pilot flame pattern and burner flame patterns
often.
PILOT FLAME
The pilot assembly is factory preset for the proper
flame height. Alterations may have occurred during
shipping and handling. The pilot is located on the
back right hand side of the burner.
The thermocouple should be fully enveloped in the
flame. The flame should not be lifting off of the
thermocouple element.
If your pilot assembly does not meet these re-
quirements:
• Turn the adjustment screw marked pilot clockwise
to decrease or counterclockwise to increase the
flame to proper size (see Figure 14).
Do not attempt to remove the adjustment screw.
• SeeTroubleshooting, pages 12-13
Pilot
Figure 13 - Correct Pilot Flame Pattern
-
to the PILOT

INSPECTING BURNERS

Thermocouple
This is a normal and temporary situation that is not
cause for alarm. However, you may want to provide
extra ventilation to the room during this time.
Hand Held
NOTICE: You must light the pilot before using the
hand-held remote control unit. See Lighting
Instructions, page 11.
After lighting, let pilot flame burn for about one minute.
Turn control knob to ON position. Slide the selector
switch on the remote receiver to the REMOTE
position.
Note: The burner may light if hand-held remote was
on when selector switch was last turned off. You
can now turn the burner on and off with the hand-
held remote control unit.
IMPORTANT: Do not leave the selector switch in the
REMOTE or ON position when the pilot is not lit.
This will drain the battery.
Figure 14 - Locating Pilot Adjustment Screw
BURNER FLAME PATTERN
Burner flames will be steady; not lifting or floating.
Flames should go up through the middle of logset.
Flames should not "spill" to the edges of the pan or
sides of the logset.
Figure 15 shows a typical flame pattern. If burner
flame pattern differs from that described:
• Turn appliance off (see To Turn Off Gas to Appli-
ance, this page).
• See Troubleshooting , page13.
Figure 15 - Typical Flame Pattern
Remote
Pilot
Adjustment Screw
11

Advertisement

Table of Contents
loading

This manual is also suitable for:

De24dbngr/lpr

Table of Contents