Table 17 - Carlin (CHIMNEY VENT) Preliminary Burner Settings
Burner settings provided are for initial startup only. Final adjustments must be made using combustion test instru-
ments.
Boiler
Insertion
Firing
Model
Depth
Rate
4075
3.00"
0.75
4095
3.00"
0.95
4110
3.00"
1.10
5100
3.00"
1.00
5115
3.00"
1.15
5135
3.00"
1.35
Timings
Pre-purge
15 seconds
Post-purge
15 seconds
Carlin
Boiler
Burner
Model
Model
4075
EZ-LF
4095
EZ-LF
4110
EZ-LF
5100
EZ-LF
5115
EZ-LF
5135
EZ-LF
17 - OIL BURNER, NOZZLE, & AIR SETTINGS
Table 17- CARLIN PARAMETERS
Combustion
Nozzle
Liner
Mfr.
OVAL
DANFOSS
OVAL
DELAVAN
OVAL
DELAVAN
NONE
HAGO
NONE
DELAVAN
NONE
DANFOSS
ECR Oil
Burner
Part
Number
240010357
240010357
240010357
240010357
240010357
240010357
Pump
Nozzle
Pressure
Type
[PSI]
0.60x60AS
160
0.75x45W
160
0.85x60A
165
0.75x60B
175
0.85x45A
180
1.10x60AB
150
52
Air Band
Head Bar
Efficiency
Setting
0.60/0.65
25%
0.75
35%
0.75
50%
0.75
35%
0.85/1.00
40%
1.10/1.25
45%
PN 240011579 REV D [08/01/2018]
Rated
AFUE
[%]
87.0
85.0
84.0
87.0
85.0
84.0