Table 14 - Beckett NX (Direct Vent) Preliminary Burner Settings
Burner settings provided are for initial startup only. Final adjustments must be made using combustion test instruments.
TABLE 14a: BECKETT DIRECT VENT PRELIMINARY BURNER SETTINGS
Boiler
Head
Insertion
Model
Type
Depth
4075
6 Slot
2.5"
4095
6 Slot
2.5"
5100
6 Slot
2.5"
5115
6 Slot
2.5"
5135
6 Slot
2.5"
6130
6 Slot
2.5"
Timings
Pre-purge
15 seconds
Post-purge
30 seconds
17 - OIL BURNER, NOZZLE, & AIR SETTINGS
Firing Rate
Combustion
Nozzle
[GPH]
Liner
0.75
Oval
Delavan
0.95
Oval
Hago
1.00
None
Delavan
1.15
V5
Hago
1.35
V5
Delavan
1.30
V6
Danfoss
Pump
Nozzle Type
Pressure
Mfr.
[PSI]
0.60x60B
150
0.75x60B
155
0.75x45B
175
1.00x60B
140
1.10x60B
150
1.00x45B
175
TABLE14b : BECKETT /ECR PART NUMBERS
Boiler
Beckett Oil
Model
Burner
4075
NX70LC
4095
NX70LC
5100
NX70LC
5115
NX70LF
5135
NX70LF
6130
NX70LD
49
Pressure
Air
Switch
Setting
Setpoint
1.5
0.65" WC
4.0
0.65" WC
4.0
0.85" WC
1.8
0.85" WC
2.5
0.85" WC
2.0
0.65" WC
ECR Oil Burner
Part Number
240007531
240009393
240007532
240009395
240009396
240007533
PN 240011579 REV D [08/01/2018]