Table 15 - Riello 40F Chimney Vent Preliminary Burner Settings
Burner settings provided are for initial startup only. Final adjustments must be made using combustion test
instruments.
TABLE 15: RIELLO 40F CHIMNEY VENT PRELIMINARY BURNER SETTINGS
Boiler
Head
Model
Type
4075
Reverse
4095
Standard
4110
Standard
5100
Standard
5115
Standard
5135
Standard
6130
Standard
6145
Standard
6165
Standard
7165
Standard
7180
Standard
7190
Standard
Timings
Pre-purge
17 - OIL BURNER, NOZZLE, & AIR SETTINGS
Inser-
Firing
Com-
tion
Rate
bustion
Depth
[GPH]
Liner
2.75"
0.75
1.75"
0.95
1.75"
1.10
2.75"
1.00
1.75"
1.15
1.75"
1.35
2.75"
1.30
1.75"
1.45
1.75"
1.65
2.75"
1.65
1.75"
1.80
1.75"
1.90
12 seconds
Riello
ECR Oil
Boiler
Oil
Burner Part
Model
Burner
Number
Model
4075
40F3
550003548
4095
40F3
550003549
4110
40F5
550003550
5100
40F5
550003551
5115
40F5
550003552
5135
40F5
550003553
Nozzle
Nozzle
Mfr.
Type
Oval
Delavan
0.65x60W
Oval
Delavan
0.75x90B
Oval
Delavan
1.00x90B
None
Delavan
0.75x60B
None
Delavan
1.00x80B
None
Delavan
1.20x80B
V6
Delavan
1.00x45B
V6
Delavan
1.25x70B
V6
Delavan
1.25x80B
V7
Delavan
1.35x60B
V7
Delavan
1.35x70B
V7
Delavan
1.50x70B
Boiler
Model
6130
6145
6165
7165
7180
7190
50
Pump
Pres-
Head
sure
Setting
Setting
[PSI]
150
1
175
3
125
1
175
1
130
2
125
3
175
2
135
4
175
2
150
4
175
2
160
3
Riello
ECR Oil
Oil
Burner Part
Burner
Number
Model
40F5
550003554
40F5
550003555
40F10
550003556
40F5
550003557
40F10
550003558
40F10
550003559
PN 240011579 REV D [08/01/2018]
Rated
Air
AFUE
Efficiency
[%]
3.6
87.0
5.3
85.0
3.1
84.0
2.4
87.0
2.8
85.0
3.4
84.0
3.6
87.0
4.0
85.0
2.8
84.0
8.0
87.0
3.4
85.0
3.2
84.0