Symptom-To-Fru Index; Error Messages - Lenovo ThinkPad L470 Hardware Maintenance Manual

Hide thumbs Also See for ThinkPad L470:
Table of Contents

Advertisement

Symptom-to-FRU index

This section contains following information:
"Error messages" on page 39
"Beep errors" on page 41
"No-beep symptoms" on page 42
"LCD-related symptoms" on page 42
"Intermittent problems" on page 43
"Undetermined problems" on page 43
The symptom-to-FRU index in this section lists symptoms and errors and their possible causes. The most
likely cause is listed first, in boldface type.
Note: Do the FRU replacement or other actions in the sequence shown in the column headed "FRU or
action, in sequence." If replacing a FRU does not solve the problem, put the original part back in the
computer. Do not replace a nondefective FRU.
This index can also help you determine, during regular servicing, what FRUs are likely to need to be
replaced next.
A numeric error is displayed for each error detected in POST or system operation. In the displays, n can
be any number.
If no numeric code is displayed, check the narrative descriptions of symptoms. If the symptom is not
described there, go to "Intermittent problems" on page 43.
Note: For a device not supported by diagnostic codes in the ThinkPad notebook computers, see the
manual for that device.

Error messages

• Message: 0177: Bad SVP data, stop POST task.
Solution: Checksum of the supervisor password in the EEPROM is not correct. The system board
should be replaced. Have the computer serviced.
• Message: 0183: Bad CRC of Security Settings in EFI Variable. Enter ThinkPad Setup.
Solution: Checksum of the Security settings in the EFI Variable is not correct. Enter ThinkPad Setup
to check security settings, press F10, and then press Enter to restart the system. If you still have a
problem, have the computer serviced.
• Message: 0187: EAIA data access error.
Solution: The access to EEPROM is failed. Have the computer serviced.
• Message: 0188: Invalid RFID Serialization Information Area.
Solution: The EEPROM checksum is not correct (block # 0 and 1). The system board should be replaced,
and the box serial number must be reinstalled. Have the computer serviced.
• Message: 0189: Invalid RFID configuration information area.
Solution: The EEPROM checksum is not correct (block # 4 and 5). The system board should be replaced,
and the universally unique identifier (UUID) must be reinstalled. Have the computer serviced.
• Message: 0190: Critical low-battery error.
Solution: The computer turned off because the battery power is low. Connect the ac power adapter to
the computer and charge the batteries.
• Message: 0191: System Security - Invalid remote change requested.
.
Chapter 4