6 WARNING - This cooker must be earthed
G A S - R A N G E
Data badge
Appliance class
Electrical supply
Gas category
Type of gas
Gas pressure settings
Pressure test point
Burner Aeration
Burner / Element
Hob - small x 2
Hob - medium x 3
Hob - large
Hob - wok
Grill
Main Oven
E L E C T R I C A L S U P P LY / L O A D
Electrical supply
240 V
Oven Lamps / Fans
Lamps
Cooling fans
T E C H N I C A L D A T A
Lower part of the front frame
Class 1 - freestanding cooker
220 - 240 V
Natural Gas I2H & LP Gas I3+
Please see data badge for your specified gas type. Can be converted from
natural gas to LPG. Never attempt to convert an appliance unless the data
badge states you can.
G20 Natural gas @ 20 mbar
G30 Butane @ 28-30mbar
G31 Propane @ 37mbar
Use the oven injector.
Fixed
Nat Gas
LPG
(kW)
Injector
(kW)
1.00
77
2.00
104
3.00
129
4.00
152
2.40
115
180
2.50
amal
Max load (W)
70
25 W each
10 W each
Injector
1.00
50
2.00
70
3.00
87
4.00
100
2.40
76
2.40
70 amal
28
Butane g/h
Propane g/h
73
72
145
143
218
215
291
286
176
172
182
179