ERGA04~08E + EHBH/X04+08E
Daikin Altherma 3 R W
4P629085-1C – 2022.05
2
Malfunctioning
Room
Main zone
Additional zone
Space heating/cooling
Setpoint screen
Control the leaving water temperature for the main zone via setpoint screen [2]
Main zone.
See
"10.3.5 Setpoint
screen" [
Schedule
Indicate if the temperature of the leaving water is defined according to a schedule
or not.
Influence of the LWT setpoint mode [2.4] is as follows:
▪
In Fixed LWT setpoint mode, the scheduled actions consist of desired leaving
water temperatures, either preset or custom.
▪
In Weather dependent LWT setpoint mode, the scheduled actions consist of
desired shift actions, either preset or custom.
#
Code
[2.1]
N/A
Heating schedule
Define a heating temperature schedule for the main zone via [2.2] Heating
schedule.
See
"10.4.3 Schedule screen:
Cooling schedule
Define a cooling temperature schedule for the main zone via [2.3] Cooling
schedule.
See
"10.4.3 Schedule screen:
[2] Main zone
Setpoint screen
[2.1] Schedule
[2.2] Heating schedule
[2.3] Cooling schedule
[2.4] Setpoint mode
[2.5] Heating WD curve
[2.6] Cooling WD curve
[2.7] Emitter type
[2.8] Setpoint range
[2.9] Control
[2.A] Ext thermostat type
[2.B] Delta T
[2.C] Modulation
[2.D] Shut off valve
[2.E] WD curve type
4
145].
Description
Schedule:
▪
0: No
▪
1: Yes
4
Example" [
151].
4
Example" [
151].
10
Configuration
|
Installer reference guide
167