Installation; Use And Maintenance - DeLonghi PALACE 1800/2 Instruction And Installation Booklet

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 6
DATA SHEET
[Fig. 4]
MODEL
Dimension LxHxP
Distance between the
brackets[LfxHf]
Minimum distance
from the floor
Depth from the wall
INSTRUCTIONS FOR WALL MOUNTING
Ensure a minimum distance from the floor of 10 cm.
Preparation of wall brackets:
- The bracket must be inserted in the outermost guide of the wall slide.
- The radiator is inserted into the outermost hollow of the bracket.

Installation

[Fig. 1 e 2]
o Carefully mark the holes in the wall brackets
ground 10 cm);
o Drill 8 mm diameter holes, with a minimum depth of 65 mm, and insert the wall plugs
o Screw the wall slides
into the wall plugs
D
4
o Avvitare per metà le viti
D
o Insert the brackets
in the wall slides
D
3
o Put the caps
on the slides
D
1
o Hang the radiator
on the brackets, making sure that the hollows of the brackets fit on the radiator collector.
A
o Position the level on the radiator and if it is not perfectly vertical, adjust the upper brackets through the screws
with the aid of the screwdriver.

USE AND MAINTENANCE

In order to obtain the best performances of product we suggest the following ways of installation:
• The system water's pH must be between 6.5 and 8 and the hardness between 12-14° f.
• Water temperature: T in=75°C; T out=65°C; T average=70°C; T max=90°C.
• Testing air room temperature: 20°C (∆T 50°C).
• Standard UNI-CTI 8065 requires that the waters used to fill a heating system undergo a prior treatment
to protect the heating system from corrosion and encrustation, without making any distinction between
aluminium, steel and cast iron.
• Vent the radiator before using it.
• Children must be supervised to ensure that they do not play with the appliance.
• Among the various additives used in the water there is a film-forming aliphatic polyamine-based product
called Cillit-HS 23 Combi.
• For maintenance do not use abrasive products and solvent to clean the radiator's surfaces, but clean the
surface with damp cloths.
• Do not isolate the radiator unless it is equipped with automatic safety valve.
• Do not load or hang excessive weights: the capacity of these structures is calculated to support Max 2Kg.
• Test the system to check the tightness of the fittings.
PALACE 1800/2
362x1852x61 mm
258x1419 mm
D
with the tape measure and level (minimum radiator height from the
F
with the 4.5x60 mm diameter screws
D
nelle staffe
dalla parte dell'incavo più piccolo.
3
2
D
; they will stop against the head of the screws
4
D
4
PALACE 1800/3
544x1852x61 mm
439x1419 mm
100 mm
97 mm
[Fig. 4]
[Fig. 5]
[Fig. 6]
F
into the wall.
E
D
2
PALACE 1800/4
725x1852x61 mm
621x1419 mm
.
D
2
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Palace 1800/3Palace 1800/4

Table of Contents