FONA XDG
Operating Instructions
English

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the XDG and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Fona XDG

  • Page 1 FONA XDG Operating Instructions English...
  • Page 2: Table Of Contents

    FONA XDG – Operating Instructions FONA XDG Operating Instructions English Edition Version 141001 October 2014 Code 69 550 70110 Manufactured by FONA S.r.l. Via Galilei 11 - 20090 Assago (MI) Italy Distributed by FONA Dental s.r.o. www.fonadental.com Stefanikova 7 SK-811 06 Bratislava, Slovakia Table of Contents INTRODUCTION ........
  • Page 3: Introduction

    Purpose The FONA XDG X-ray equipment is designed to fulfil the needs for high resolution intra-oral radiography in the general dental practice. The systems can be configured for wall or mobile solutions. The Operating Instructions and the Service and Installation Manual supplied with the system are integral part of the product.
  • Page 4: Technical Data

    FONA XDG – Operating Instructions 2. TECHNICAL DATA System Supply Line Voltage 115 V (from 99 V to 132 V in sub-ranges depending on THA mounted) 230 V (from 198 V to 264 V in sub-ranges depending on THA mounted)
  • Page 5: Operating Instruction

    FONA XDG – Operating Instructions 3. OPERATING INSTRUCTION The Control Panel Device for emission of ionizing radi- Maxillary incisor ation on request Indication of system turned on and Maxillary canine or premolar ready Maxillary molar Irradiation Alarm Mandibular incisor mAs display, the controlled...
  • Page 6: User Functionality Of Tipset Timer

    FONA XDG – Operating Instructions User Functionality of TipSet Timer Before using the timer make sure that the exposure indexes for film and sensor have been set in memory. EXPOSURE INDEX 0.32 0.63 1.25 XIOS FILM FILM SENSOR SENSOR FILM CDR Sensor by Shick Technologies Inc., XIOS Sensor by Sirona Dental Systems GmbH...
  • Page 7: Operation

    FONA XDG – Operating Instructions Operation Turn on the line voltage supply with the switch YELLOW below the timer LIGHT 1. Have the patient remove any provisional ob- ject in the mouth which may affect image quality. Position the image receptor where needed and orientate the tube-head accordingly.
  • Page 8: The Timing Table

    6. ELECTROMAGNETIC COMPATIBILITY Electromagnetic Emissions The FONA XDG is suitable for use in the specified electromagnetic environment. The purchaser or user of the FONA XDG should assure that it is used in an electromagnetic environment as described below. Emission Test...
  • Page 9: Electromagnetic Immunity

    FONA XDG – Operating Instructions Electromagnetic Immunity The FONA XDG is suitable for use in the specified electromagnetic environment. The customer or user of the FONA XDG should assure that it is used in an electromagnetic environment as described below.
  • Page 10: Appendix A Systems And Spare Parts

    FONA XDG – Operating Instructions Appendix A Systems and Components FONA XDG Systems @ 230 V FONA XDG Systems @ 120 V Code Description Code Description 97 586 62320 Wall Syst. Arm S 30 cm 230V 97 546 62320 Wall Syst. Arm S 30 cm 120V 97 586 62620 Wall Syst.
  • Page 11: Appendix B Icons

    FONA XDG – Operating Instructions Appendix B Icons IEC Type B Compliance to European Community Equipment Requirements X-ray On Compliance to Canadian and US Irradiation Standards Line voltage supply On - System Examine Annexed Documentation Ready Off (Disconnected from Line voltage...
  • Page 12: Appendix C Exposure Table

    7.00 8.75 11.20 FONA XDG Exposure Factors in mAs CDR Sensor: Schick Technologies. Inc. Long Island City, NY, USA XIOS Sensor: Sirona Dental Systems GmbH, Bensheim, Germany Film D: Kodak Ultraspeed, Agfa Dentus M2 – Film E: Kodak Ektaspeed Plus - Film F: Kodak Insight...
  • Page 13: Appendix D Alarm Conditions

    FONA XDG – Operating Instructions Appendix D Alarm Conditions Timer Alarm Conditions Code Fault /Error Signal Reset By acknowledgement X-ray requested during Green lamp on the panel or when A 01 cool-down period (System Ready) flashing system has cooled down...
  • Page 14: Appendix E Identification Labels

    FONA XDG – Operating Instructions Appendix E Identification Labels 14/16 69 550 70110 141001...
  • Page 15: Appendix F Cooling Curves

    FONA XDG – Operating Instructions Appendix F Cooling Curves COOLING CURVE OF X-RAY INSERT Time (min) COOLING CURVE OF TUBE HOUSING ASSEMBLY Time (min) 141001 69 550 70110 15/16...
  • Page 16 We reserve the right to make any alterations which may be required due to clinical improvements FONA XDG Operating Instructions – English Edition 141001 FONA Dental s.r.o. FONA S.r.l. *6955070110* Via Galilei 11 - 20090 Assago Stefanikova 7 SK-811 06...