Steps
11. Remove compressor
Unsolder the welding joint connecting the
a
capillary, valves and the outlet pipe of
condenser to remove the capillary. Do not
block the capillary with welding slag
during unsoldering.
Remove the 2 screws fixing the gas valve
b
and unsolder the welding joint between
the gas valve and the air-return pipe to
remove the gas valve. (NOTE: Discharge
the refrigerant completely before
unsoldering; when unsoldering, wrap the
gas valve with a wet cloth completely to
avoid damage to the valve caused by high
temperature).
Remove the 2 screws fixing the liquid
valve and unsolder the welding joint
connecting the liquid valve to the Y-type
pipe to remove the liquid valve.
c
Unsolder pipes connecting with
compressor.
d
Remove the 3 foot nuts on the compressor
and then remove the compressor.
112
Procedure
Service Manual
4-way valve
cut-off valve
compressor
nuts