  • Page 1 MixRite E-300 -User Guide...
  • Page 2: Table Of Contents

    P6 - Additive flow and motor % with pressure…………………..10 P7 - Kits list……………………………………………………..11-12 P8 - Pump spare parts…………………………………….…………13 Page 2 of 13 Tefen Flow and Dosing Technologies LTD. Kibbutz Nahsholim 3081500 Israel Tel. 972 4 6395554 Fax. 972 4 6390813 info@tefentech.com...
  • Page 3: Introduction - Safety Guidelines

    Document no: P.I - 10.26/05 Introduction TEFEN E300 fertilizer pump is designed to ensure precise amount of fertilizer to your irrigation system. E-300 electric dosing pump directly injects liquid additives into water lines. The E300 operate by an AC/DC irrigation controller.
  • Page 4: P1. Technical Data

    • Max – 5.0 bar (72 psi) Pressure • Up to 40°C Ambient Temperature Material Diaphragm Santoprene Piston Viton Pump house Page 4 of 13 Tefen Flow and Dosing Technologies LTD. Kibbutz Nahsholim 3081500 Israel Tel. 972 4 6395554 Fax. 972 4 6390813 info@tefentech.com www.tefentech.com...
  • Page 5: P2. Assembly Instructions And Installation

    Horizontal position Flow Vertical position NOTE Only qualified electrician certificates may change the wiring of the pump Page 5 of 13 Tefen Flow and Dosing Technologies LTD. Kibbutz Nahsholim 3081500 Israel Tel. 972 4 6395554 Fax. 972 4 6390813 info@tefentech.com www.tefentech.com...
  • Page 6: P3. Set Pump Parameter And Operation

    3.2-Select the mode, execute the following steps: 1- Press the buttons as shown below: (P)→(+) →(P)→(+) 2- Press (P) to change mode options: Page 6 of 13 Tefen Flow and Dosing Technologies LTD. Kibbutz Nahsholim 3081500 Israel Tel. 972 4 6395554 Fax. 972 4 6390813 info@tefentech.com...
  • Page 7 5- Operation cycle a- Up to 4 bar- continuous. b- 4 - 5 bar - 1.5 hours- Page 7 of 13 Tefen Flow and Dosing Technologies LTD. Kibbutz Nahsholim 3081500 Israel Tel. 972 4 6395554 Fax. 972 4 6390813 info@tefentech.com...
  • Page 8: P4. Troubleshooting

    3- Display E r 3 - Under-voltage (Driver Low voltage) supply a- The Motor turns-off and Red light appears. Page 8 of 13 Tefen Flow and Dosing Technologies LTD. Kibbutz Nahsholim 3081500 Israel Tel. 972 4 6395554 Fax. 972 4 6390813 info@tefentech.com...
  • Page 9: P5. Maintenance

    Check function and noise * After using aggressive chemicals, it is recommended to flash the system with clean water Page 9 of 13 Tefen Flow and Dosing Technologies LTD. Kibbutz Nahsholim 3081500 Israel Tel. 972 4 6395554 Fax. 972 4 6390813 info@tefentech.com...
  • Page 10: P6 - Additive Flow And Motor % With Pressure

    MixRite E-300 -User guide Document no: P.I - 10.26/05 P6. Additive flow rate MixRite E-300 Value Value Page 10 of 13 Tefen Flow and Dosing Technologies LTD. Kibbutz Nahsholim 3081500 Israel Tel. 972 4 6395554 Fax. 972 4 6390813 info@tefentech.com...
  • Page 11: P7 - Kits List

    MixRite E-300 -User guide Document no: P.I - 10.26/05 P7. MixRite E-300 STD KIT Qty. Descriptions Part No. Image 1.00 FEMALE PIPE COUPLING - 1/2"" 12010308088 1.00 FEMALE PIPE COUPLING - 3/4" BLUE 12010312128 1.00 PIPE HEX NIPPLE - 3/4" NPT 12022212123 10.00...
  • Page 12 MixRite E-300 -User guide Document no: P.I - 10.26/05 MixRite E-300 PVDF KIT Assembly Instructions Page 12 of 13 Tefen Flow and Dosing Technologies LTD. Kibbutz Nahsholim 3081500 Israel Tel. 972 4 6395554 Fax. 972 4 6390813 info@tefentech.com www.tefentech.com...
  • Page 13: P8 - Pump Spare Parts

    MixRite E-300 -User guide Document no: P.I - 10.26/05 P8. MixRite E-300 - Spare parts Item no Image Part No. Descriptions 38000000254 Power supply Controller STD for 38000000273 electric pump 38000000356 Motor Gasket 38000000390 Upper Housing 38000000391 Valve Kit (Viton)