ASSEMBLING YOUR AIR CONDITIONER
Installation & Assembly Instructions
Important Considerations
1. Before installing the appliance, you must read the manual carefully to
get the safety information and notes.
2. Unit refrigerant charge amount: refer to unit name plate marking.
3. A leak test must be done after the installation is completed.
4. It is a must to do the safety inspection before maintaining or repairing
an air conditioner using combustible refrigerant in order to ensure
that the fire risk is reduced to minimum.
5. It is necessary to operate the machine under a controlled procedure
in order to ensure that any risk arising from the combustible gas or
vapor during the operation is reduced to minimum.
Introduction to Refrigerants R32
1.Site Safety
Open Flames
Prohibited
3.Installation Safety
- Refrigerant Leak Detector
- Appropriate Installation Location
- The left picture is the schematic diagram of arefrigerant leak detector.
Please note that:
1. The installation site should be in a well-ventilated condition.
2. The sites for installing and maintaining an air conditioner using Refrigerant R32 should be
free from open fire or welding, smoking, drying oven or any other heat source higher than
548
which easily produces open fire.
3. When installing an air conditioner, it is necessary to take appropriate anti-static measures
such as wear anti-static clothing and/or gloves.
4. It is necessary to choose the site convenient for installation or maintenance wherein the air
inlets and outlets of the indoor and outdoor units should be not surrounded by obstacles
or close to any heat source or combustible and/or explosive environment.
5. If the indoor unit suffers refrigerant leak during the installation, all the personnel should go
out till the refrigerant leaks completely for 15 minutes. If the product is damaged, it is a
must to carry such damaged product back to the maintenance station and it is prohibited to
weld the refrigerant pipe or conduct other operations on the user's site.
6. It is necessary to choose the place where the inlet and outlet air of the indoor unit is even.
7. It is necessary to avoid the places where there are other electrical products, power switch
plugs and sockets, kitchen cabinet, bed, sofa and other valuables right under the lines on
two sides of the indoor unit, and also prevent mechanical damage from occurring.
Ventilation
Necessary
2.Operation Safety
Mind Static
Electricity
Protective Clothing
and Anti-Static
17
Must Wear
Mobile Phone
Gloves
Don't Use