The connection set KWL-MZB-VSAP, which is available as an accessory, is required for the connection of the MultiZo-
neBox and adapter plate. Contents:
12 pcs plastic fitting
2 pcs wide mounting bracket
2 pcs narrow mounting bracket, incl. screws
1.
Remove the dust protection caps on the required connectors.
Ensure that small parts do not fall into the MultiZoneBox, as this can result in faults or noise generation during
operation .
2.
Then insert the right number of plastic fittings from the accessory set KWL-MZB-VSAP and lock into the connectors.
3.
Attach the narrow mounting bracket A from the accessory set KWL-MZB-VSAP to the adapter plate on the left and
right (see image above). The sealing strip on the edge of the adapter plate can be removed.
4.
Attach the wide mounting bracket B from the accessory set KWL-MZB-VSAP to the MultiZoneBox. The casing screws
are used for attachment.
Accordingly, loosen the four casing screws and reattach with the mounting bracket.
The factory-mounted mounting brackets must be removed in advance, if necessary!
5.
Screw the connection screw C from the accessory set KWL-MZB-VSAP into one side of the adapter plate and mount
the MultiZoneBox here using the slotted hole in the mounting bracket. Then bring the mounting brackets together on
the opposite side and attach with the second connection screw.
6.
Now attach the MultiZoneBox using the two remaining attachment points (connection side ventilation unit / electrical
connection side). Then check the tightness of all attachment points.
Fig .5
A
C
B
3
Fig .6
Fig .7
EN

Advertisement

loading