(1. 2) 1 Pulse Trigger SYNC-NON RESET Picture Output Timing (at Time of Internal Sync)
Trigger*
1
VD OUT*
3
VIDEO INDEX
Video output
*1: Externally input signal
*2: Exposure time is determined by the setting of "(1.3) Changing each setting in E.TRG mode".
As long as there is no external sync input, the internal VD will be output when the rear panel HD/VD signal
input/output switch is set to the INT side.
*3: Video is output at the falling edge of the internal VD following completion of the exposure period.
The video and the VIDEO INDEX have a paired relationship.
Note:
When the next trigger is input before completion of the output of the video corresponding to the trig-
ger, there will be an effect on the video.
About 1 s
Exposure period*
2
525H (Partial scanning OFF)
175H (Partial scanning ON)
Negative polarity mode
Exposure period*
2
Positive polarity mode