IENGLISHI
13.
Install enclosure cover and when safe to do so, energize the system.
(Note: The contactor may not close until a computational observation time of
between 0 - 10 minutes. The algorithm must be satisfied the system will
remain below 80% of the rated main breaker and other values included in it.
This is partially dependent on the setting of the timer adjustment screw
(white) on the control board. If this observation time is too long, it can be
adjusted by turning this dial setting counter-clockwise but this should not be
set below 1 minute to avoid undesired operation.)
SETTINGS CHARTS
See the setting diagram chart on the next page and continued instructions
Consult the inside cover of the device for settings. There you will find the setting
applies to the device model and iteration you have. Only use the setting
appropriate for the model of the device. For example, the settings for an
EVEMS240-100 are for electrical service sizes of 100A and under. While the
settings for EVEMS240-200 are for service sizes of 125A and over. The chart
provided here is for reference only and may differ from the generation you are
using.