1.
Remove the two cover screws and enclosure cover.
2.
Attach the device securely to the desired location. Do not mount with
the cover plate facing down.
3.
Remove the black internal control partition by unscrewing the two
screws inside the enclosure.
4.
Install current monitoring devices on the main service wires to be
monitored by clipping them onto each main line paying attention to the
arrow inside the window and labeling that indicates the direction of
current flow and orientation of connection. Current monitoring devices
should be installed so that no part of them will directly conduct
electricity from exposed live parts. Ensure the closing clip is secured shut
and fastened with a zip tie. Fasten the current monitoring devices in
place with the zip-ties. Review and observe all local safety procedures
when installing and working near live parts.
5.
Ensure main line lugs have not come loose with the installation of
current monitoring devices.
6.
Install the current monitoring device wire leads from the service area to
the device control partition area ensuring the polarity of the leads
remains as from the factory. If connectors are disconnected the factory-
installed polarity must be maintained. (DO NOT coil wires near any other
120/240V wires as this may cause improper operation. DO NOT short
wire leads together or to ground at any time. Install leads with
mechanical protection from damage.)
7.
Insert the two blue current monitoring device connectors into the
corresponding two blue receptacles on the control board. Maintain wire
polarity in the blue connectors and ensure wires and connectors are
7