IENGLISHI
seated well in each receptacle. (the correct polarity should have the red
wire closest to the wall of the partition while the connector is plugged
into the socket)
8. S
et up switches and observation time dial as indicated in the chart and
diagram later on in this document or the back of the cover of the enclosure.
These switches and dial are located on the control board.
9.
Re-install the cover of the control partition inside the enclosure by
reinstalling the screws removed previously and tightening them until snug. Be
sure not to pinch any wires or strip the screws.
10.
Install electrical lines from the supply breaker for the controlled device to
the marked LINE SIDE of the contactor and bonding/ground attachment.
Ensure proper torquing of wires.
11.
Install electrical lines from end device to be controlled (ie: EV charger) to
LOAD SIDE of contactor and bonding/ground as required by local electrical
codes. Ensure proper torquing of wires.
12.
When safe, energize the device and check the control board for the red
light to be on indicating power and the green output light is not flashing. If the
green light is flashing continuously, it indicates that there is little to no current
being read by one or both of the current monitoring devices. Most operating
installations should have some current flow on both main lines so this may
indicate improper installation of one or both of the current monitoring
devices. The green LED will stop flashing when it senses some current on both
main lines. Although it will still operate with one current monitoring device
not reading current the installation should be verified. To do this, turn on a
high current 240V device in the electrical system and the LED should stop
flashing. If it does not recheck the current monitoring device installation from
step 3 ensuring that the polarity of the current monitoring devices is correct
and all connections are secure. If this is all correct, contact the manufacturer.