This device has a monitoring system that can protect an electrical distribution circuit by
switching a load on or off based on its main breaker size and on what the system usage is. It will
act to prevent systems connected to it from overloading the electrical distribution circuit. It
does so by turning off the power to the load connected to it for the duration that the
computational algorithm determines it is necessary as it relates to the main breaker sizing.
Voltage
Main Lug Wire Size & Torque
Contactor Insulation System
Frequency
Operation ambient temp.
Dimensions*
6"(H) x 8"(W) x 4"(D)
203mm(H) x 152mm(W) x 101mm(D)
*Dimensions and weight are approximate figures and subject to change without notice.
Model Naming Convention
Device Name, Voltage – Max Main Service Breaker Size
EVEMS240 – 100
EVEMS240 – 200
Operation After Power Outage
In the event of a power outage, the device automatically restores the power
supply to the vehicle charging station or receptacle when power returns and the
algorithm determines that the current draw and other factors are under the
setpoint for the determined period set by the installer.
240/208V AC single phase
14 - 4 AWG (Cu only)
Torque for Cu 75°C: 40 in-lbs
120°C, Class B
50 or 60 Hz
34°F to 104°F (1°C to 40°C)
Weight*
5 lb
(2.27kg)