Single Stage
Multi-Stage
Heat Pump
Heat Pump with Dual Fuel Single or Two Compressor Systems with up to 2 Stages of Fossil fuel Heat
SPECIFICATIONS
Electrical Rating:
Input-Hardwire ....................................................... 20 to 30 VAC
Terminal Load ................................................................ 1.0A per terminal, 2.5A maximum all terminals combined
Setpoint Range .............................................................. 45° to 99°F (7° to 37°C)
Operating Ambient ........................................................ 32°F to +105°F (0° to +41°C)
Operating Humidity ....................................................... 90% non-condensing max.
Shipping Temperature Range ......................................... -40° to +150°F (-40° to +65°C)
Dimensions Interface ..................................................... 4-1/2"H x 6"W x 1-1/4"D
Dimensions Control ....................................................... 5-1/2"H x 5-3/4"W x 1-1/2"D
CAUTION
!
WARNING
!
2
Applications
Gas, Oil, Electric, Heat Only, Cool Only or Heat Cool Systems
Gas, Oil, Electric, Heat Only, Cool Only or Heat Cool Systems
Single or Two Compressor Systems with up to 2 Stages of Aux / Em Heat
3
4
5
5
6
7
8
8
10
ATTENTION: MERCURY NOTICE
This product does not contain mercury. However, this product
may replace a product that contains mercury.
Mercury and products containing mercury must not be
discarded in household trash. Do not touch any spilled
mercury. Wearing non-absorbent gloves, clean up any spilled
mercury and place in a sealed container. For proper disposal of
a product containing mercury or a sealed container of spilled
mercury, place it in a suitable shipping container. Refer to
for location to send product
containing mercury.
1/1
2/2
4/2
4/2