Advertisement

User
Manual
CLUSTER B4 FC
USER MANUAL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CLUSTER B4 FC and is the answer not in the manual?

Questions and answers

Summary of Contents for ROXX CLUSTER B4 FC

  • Page 1 User Manual CLUSTER B4 FC USER MANUAL...
  • Page 2: Table Of Contents

    1.1. General Preventive Measures 1.2. Regulations for equipment that connects to power mains 1.3. Technical warnsigns and explanation 2. Introduction 2.1. About us 2.2. CLUSTER B4 FC 3. General Product Information 3.1. Scope of delivery 3.2. Control Functions 3.3. Features 4.
  • Page 3 User User Manual Manual 7. Technical Data / Diagrams 7.1 Technical drawings and measurements 7.2 IP Rating 7.3 Technical Data 7.4 DMX-Charts / Color Macro Charts / CCT Chart 7.5 RDM Templates 8. Troubleshooting 9. Manufacturer´s Declaration...
  • Page 4: Safety Informations

    1.1.1. Please read, understand and follow the instructions. 1.1.2. Store the instructions and information in a safe place. Best solution is the ring binder provided by ROXX. 1.1.3. Follow all safety warnings. Under no circumstances remove safety warnings or other information from the equipment.
  • Page 5: Regulations For Equipment That Connects To Power Mains

    User User Manual Manual 1.1.20. Observe all disposal laws applicable in your country. Especially for the packaging. 1.1.21. Plastic bags are not a toy! Keep away from children! 1.1.22. Please note that changes or modifications which are not approved by the party responsible for compliance will void the user’s authority to operate the device.
  • Page 6: Technical Warnsigns And Explanation

    User User Manual Manual 1.3. Technical warnsigns and explanation In order to prevent the risk of an electric shock, under no circumstances remove the cover/back or open the unit in any way! No user serviceable parts are inside. Service, maintenance and repairs should only be done by qualified service personnel or the manufacturer.
  • Page 7: Introduction

    This ensures innovative, easy-to-use and performance- oriented solutions, which provide added value for our customers. Made to last Recommended for permanent outdoor use, most ROXX products feature additional corrosion protection and en- ®...
  • Page 8: General Product Information

    Manual 3. GENERAL PRODUCT INFORMATION 3.1. Scope of delivery 1x CLUSTER B4 FC Power cord with plug (EU country specific, if not ordered differently) Pre-installed PUK We´re offering a wide range of professional accessories (optional). Please see under menu 6 or at our website www.roxxlight.com...
  • Page 9: Installation & Setup

    4. INSTALLATION & SETUP 4.1 Physical Installation and Rigging ROXX CLUSTER B4 FC may be installed in any orientation. For this purpose the product provides several options: Standing: The fixtures Yoke includes two M8 inner threads to install the optional ROXX YOKE FLOOR EXTENSION.
  • Page 10 User User Manual Manual 2. By included yoke with several mounting points: Multiple mounting points: A: 3x Camlock with ¼ turn adapters B: 3x M12 / ½“ C: 1x TV Spigot Additional Yoke anchor points: In the delivery state, the yoke is preinstalled in such a way that the individual eyes can be rotated +/-20° in the pan. Each CLUSTER device also provides side anchor points for the yoke so that the device can then be rotated either clockwise or counterclockwise so that the individual eyes can then be adjusted +/-20°...
  • Page 11 User User Manual Manual 3. Using optional ROXX RIGGING BRACKET For seemless connection of multiple Blinders, to avoid gaps due to bracing of the truss structure by variable, sliding mounting positions. Product Clustering All CLUSTER products can be easily connected both horizontal and vertically, by using the integrated C-Lok system.
  • Page 12 User User Manual Manual 3. Make sure that the C-Lok hooks are turned counterc- lockwise (CCW) to the end-position first before you finally lock the C-Loks. 4. For locking all C-Lok´s, please turn them clockwise into end-position. Note: As soon as both dot indicators are in line, the C-Lok is securely locked Maximum Tensile and Torsion Load Before setting up Cluster configurations, be aware of the maximum tensile and torsion load, listed...
  • Page 13 With 2x Omega Bracket Max. Tension Load: 49kg Max. Tension Load: 90kg Max. Torsion Load: 5.041 Nmm Max. Torsion Load: 10.808 Nmm 3. Using optional ROXX RIGGING BRACKET with 2x Mounting Clamps Max. Tension Load: 72kg Max. Torsion Load: 6.326 Nmm...
  • Page 14: Connections

    User User Manual Manual Important Note: Please be aware of using the centering PUK for safe RIGGING BRACKET installation to the CLUSTER device. 4.2 Connections* A: Mains In: IP65 Power input connector with rubber sealing cap.Connect using the provided power cable (when not in use, always close with rubber sealing cap).
  • Page 15: Ac Power

    Manual 4.2.1. AC Power The CLUSTER B4 FC operates on any 100–260 V, 50/60 Hz AC mains power supply with a maximum power con- sumption of 220W. Connect the fixture to AC power using the supplied cable or a similar one with Neutrik powerCON TRUE1 NAC3FX-W or a compatible type, to ensure the correct ingress protection (IP).
  • Page 16: Operation

    Once the fixture is connected to AC power, the boot process starts and the following information will appear on the display: “Ready to ROXX”, the product name and the current software version. After this process, the fixture is ready for operation, and starts in the previous- ly enabled mode.
  • Page 17 User User Manual Manual Display Off Pressing ESC + arrow down simultaneously the display backlight function will set to off and the display will turn off immediately. Once a control is pressed the display backlight will turn on. Manual display flip function* The fixture includes an auto display flip function by default.
  • Page 18: Configuration

    User User Manual Manual 5.4 Configuration Home Screen After boot process the fixture is ready for operation and starts in the previously enabled mode. At home screen the following information will appear, depending on the current operating mode: DMX Adress Operating Mode (DMX Mode, Quick Light or Standalone Mode) Next available DMX address depending on the fixtures DMX footprint External Data protocol (DMX).
  • Page 19: Stand Alone

    User User Manual Manual Level 1 Level 2 Menu DMX Mode DMX Mode 1CH DWE 2CH DWE Stand Alone 4-1CH DWE Slave 4-2CH DWE Settings 9CH DWE+ System Info 8CH STROBE 12CH RGB 10CH BASIC RGB 14CH BASIC RGB 21CH STANDARD RGB 38CH STANDARD RGB 40CH EXTENDED RGB 57CH EXTENDED RGB...
  • Page 20 User User Manual Manual Auto* Select “Auto” by using the up/down arrows and press ENTER. Here at sub-menu (level 3), you can choose between 10 different Auto Effects (Effect 1 - 10) and Stop Program. Using the Up/Down arrows you can select one of the 10 Effects and confirm by pressing ENTER or step back by ESC. After confirming your preferred Effect, you can now adjust speed and brightness at level 4.
  • Page 21 User User Manual Manual Color Macro* 46 different color macros (34x matched LEE color filters, 6 LED colors and 6 different Whites) are available as presets. For each the brightness can be adjusted separately. Level 1 Level 2 Level 3 Menu Stand Alone Mode Color Macro...
  • Page 22 User User Manual Manual Quick Color* The standalone mode “Quick Color” allows a direct adjustment of the single LED colors R, G, B, A, W, Dimmer and Shutter. Level 1 Level 2 Level 3 Menu Stand Alone Mode Quick Color DMX Mode Stop Stand Alone Dimmer...
  • Page 23 User User Manual Manual * Note: Tint values = no function/neutral 001 - 127 = + green -001 to - 127 = - green * Note: Using UP/DOWN arrows at homescreen the selected CCT value can be changed in +/- 100K steps. Shutter: Please see detailed explanation for strobe effects inside DMX chart at the end of this manual.
  • Page 24: Slave Mode

    User User Manual Manual Color Settings* Here at “Color Settings” you can chose your preferred working color mode for all Stand Alone modes. Either Color Calibration or RAW. Chose Color Calibration if the fixture should work accroding to the settings at Color Calibration, either Full Calibration or CCT Calibration, RAW works according to the settings at RAW Balance, either RAW or User Calibrated.
  • Page 25 User User Manual Manual Main Menu Menu level 2 Menu level 3 Menu level 4 Description On= Flip control panel display by Display Flip <on/off> 180° (e.g. for overhead installation) Off= normal control panel display On= controls permanent on, display itself will deactivate after 60 minues of incativity Backlight <on/off>...
  • Page 26 User User Manual Manual Red 2 <0-255> Green 2 <0-255> Blue 2 <0-255> Amber 2 <0-255> White 2 <0-255> Red 3 <0-255> Green 3 <0-255> RAW Balance (affects RAW Mode individual color calibration User Calibration Blue 3 <0-255> in DMX and Stand for R,G,B,A,W Alone Modes Amber 3 <0-255>...
  • Page 27 User User Manual Manual Main Menu Menu level 2 Menu level 3 Menu level 4 Menu Level 5 Description 1CH DWE, 2CH DWE, 4-1CH DWE, 4-2CH DWE, 9CH DWE+, 8CH STROBE, 12CH RGB, 10CH BASIC RGB, 14CH BASIC RGB, 21CH STAN- DARD RGB, 38CH STANDARD RGB, 40CH EXTENDED RGB, 57CH EXTENDED RGB, 20CH...
  • Page 28: System Info

    User User Manual Manual Pixel Arrangement PIXEL 1 PIXEL 2 PIXEL 3 PIXEL 1 PIXEL 2 PIXEL 4 PIXEL 3 PIXEL 4 PIXEL 4 PIXEL 2 PIXEL 1 PIXEL 3 Dimmer Curves LINEAR EXPONENTIAL LOGARITHMIC S-CURVE 5.4.6 System Info Level 1 Menu DMX Mode Stand Alone...
  • Page 29: Accessories

    User User Manual Manual 6. ACCESSORIES Yoke 4.3 Floor Extension Rigging Bracket Art.: 13907101 Art.: 13907411 Art.: 13907201 Omega Bracket ST Case 4 pcs. / 8 pcs. Art.: 13907411 Art.: 90900002 Case 2 pcs / 4 pcs Art.: 13907511...
  • Page 30 User User Manual Manual 7. TECHNICAL DATA / DIAGRAMS 7.1 Technical drawings and measurements...
  • Page 31 7.2 IP Rating ROXX products conform to officially classified IP standard levels. CLUSTER B4 FC is rated to IP65 when using the co- vers for the housing parts. IP stands for Ingress Protection and IP65, according to classified standard, means shielded against dust and high-pressure jets of water from any side.
  • Page 32 User User Manual Manual 7.3 Technical Data Photometrics LED expected lifetime 50.000 hours Lightsource 4x 300W Red, Green, Royal Blue, Amber, Warm-White Type of optical system Reflector with Compound Eye Lens LED PWM Frequency selectable 800Hz, 1200Hz, 2000Hz, 3600Hz, 12kHz, 25kHz Beam angles (50%) 50°...
  • Page 33 User User Manual Manual 7.3 Technical Data Operator & Controller Master Dimmer, Master Dimmer Fine, Shutter, Duration, Dimmer 1-4, Dimmer 1-4 Fine, Red 1-4, Red 1-4 Fine, Green 1-4, Blue 1-4, Blue Fine 1-4, Amber 1-4, Warm- DMX Functions White 1-4, CTC 1-4, Tint 1-4, Color Macro 1-4, Color Macro Crossfade 1-4, Effect, Dimmer Curve, Dimmer Response, Redshift, Device Settings 1CH DWE, 2 CH DWE 4-1CH DWE, 4-2CH DWE, 9CH DWE+, 8CH STROBE, 12CH RGB, 10CH BASIC RGB, 14CH BASIC RGB, 21CH STANDARD RGB (default), 38CH...
  • Page 34 User Manual 7.4 DMX-Charts / Color Macro Charts / CCT Chart 1CH DWE 40CH EXTENDED RGB 2CH DWE 57CH EXTENDED RGB 4-1CH DWE 20CH DIRECT 4-2CH DWE 12CH DIRECT 9CH DWE+ 29CH DIRECT 8CH STROBE 48CH DIRECT 12CH RGB 73CH DIRECT 10CH BASIC RGB 14CH BASIC RGB 21CH STANDARD RGB (default)
  • Page 35 User Manual 12CH RGB 10CH BASIC RGB 14CH BASIC RGB 21CH STANDARD RGB (Cali- (Calibrated) (Calibrated) (Calibrated) brated / default) Red 1 Master Dimmer Master Dimmer Master Dimmer Green 1 Shutter Master Dimmer Fine Shutter Blue 1 Shutter Dimmer 1 Red 2 Green Red 1...
  • Page 36 User Manual 38 CH STANDARD RGB 40CH EXTENDED RGB 57CH EXTENDED RGB (Calibrated) (Calibrated) (Calibrated) Master Dimmer Master Dimmer Master Dimmer Master Dimmer Fine Shutter Master Dimmer Fine Shutter Duration Shutter Dimmer 1 Dimmer 1 Duration Dimmer 1 Fine Red 1 Dimmer 1 Red 1 Green 1...
  • Page 37 User Manual 38CH STANDARD RGB 40CH EXTENDED RGB 57CH EXTENDED RGB (Calibrated) (Calibrated) (Calibrated) Device Settings Color Macro Crossfade 3 Dimmer 4 Dimmer 4 Fine Red 4 Red 4 Fine Green 4 Green 4 Fine Blue 4 Blue 4 Fine CTC 4 Tint 4 Color Macro 4...
  • Page 38 User Manual 73CH 20CH DIRECT 12CH DIRECT 29CH DIRECT 48CH DIRECT DIRECT (RAW) (RAW) (RAW) (RAW) (RAW) Red 1 Master Dimmer Master Dimmer Master Dimmer Master Dimmer Green 1 Shutter Shutter Shutter Master Dimmer Fine Blue 1 Dimmer 1 Duration Shutter Amber 1 Green...
  • Page 39 User Manual 20CH 12CH 29CH 48CH 73CH DIRECT DIRECT DIRECT DIRECT DIRECT (RAW) (RAW) (RAW) (RAW) (RAW) Amber 4 Dimmer 3 Fine White 4 Red 3 CTC 4 Red Fine 3 Tint 4 Green 3 Color Macro 4 Green Fine 3 Color Macro Cross- Blue 3 fade 4...
  • Page 40 User Manual 1CH DWE (Calibrated / according to selected Tunable White settings at Stand Alone Mode, default 2900K) Function Value Setting Remark Default Dimmer 000-255 0 - 100% 2CH DWE (Calibrated / according to selected Tunable White settings at Stand Alone Mode, default 2900K) Function Value Setting...
  • Page 41 User Manual 085 - 089 Shutter open 090 - 104 Strobe 3: closing pulse (fast slow) 105 - 109 Shutter open 110 - 124 Strobe 4: random strobe (fast slow) 125 - 129 Shutter open Strobe 5: random opening pulse 130 - 144 (fast slow)
  • Page 42 User Manual 8CH STROBE MODE (Calibrated) Function Value Setting Remark Default Master Dimmer 000-255 0 - 100% 000 - 019 Shutter close 020 - 024 Shutter open 025 - 064 Strobe 1 (fast slow) 065 - 069 Shutter open Strobe 2: opening pulse 070 - 084 (fast slow)
  • Page 43 User DMX CHART Manual 12CH RGB (Calibrated) Function Value Setting Remark Default Red 1 000-255 0 - 100% Green 1 000-255 0 - 100% Blue 1 000-255 0 - 100% Red 2 000-255 0 - 100% Green 2 000-255 0 - 100% Blue 2 000-255 0 - 100%...
  • Page 44 Magenta -> Neutral (affects CTC and 128-128 Neutral RGB) 129-255 Neutral -> Green Color Macro Please see ROXX color macro chart (override RGB/CTC) 000 - 005 No function 006-105 0,1s - 10s (0,1s steps) Color Macro Cross- fade (Transition 106-214...
  • Page 45 User Manual Redshift On (hold 1,5s / affects only bet- 110-114 ween 2700-3500K ) 115-119 Redshift Off (hold 1,5s) 120-124 No function 125-129 Full Calibration (Colors & CCT / hold 3s) 130-134 CCT Calibration (RAW Colors / hold 3s) 135-139 No function 140-144 LED Frequency 800Hz (hold 3s)
  • Page 46 User Manual 14CH BASIC RGB (Calibrated) Function Value Setting Remark Default Master Dimmer 000-255 0 - 100% Master Dimmer Fine 000-255 0 - 100% 000 - 019 Shutter close 020 - 024 Shutter open 025 - 064 Strobe 1 (fast slow) 065 - 069 Shutter open...
  • Page 47 Magenta -> Neutral (affects CTC and 128-128 Neutral RGB) 129-255 Neutral -> Green Color Macro Please see ROXX color macro chart (override RGB/CTC) 000 - 005 no function 006-105 0,1s - 10s (0,1s steps) Color Macro Cross- fade (Transition 106-214...
  • Page 48 User Manual 175-179 Fan Auto (hold 3s) 180-184 Fan Silent (hold 3s) 185-189 Fan Off (hold 3s) 190-194 Fan High Power (hold 3s) 195-199 No function 200-204 Invert Mapping Off (hold 3s) 205-209 Invert Mapping CW (hold 3s) Device Settings 210-214 Invert Mapping CCW (hold 3s) (please see...
  • Page 49 User Manual 210 - 224 Strobe 9: sine wave (fast slow) 225 - 229 Shutter open Shutter 230 - 244 Strobe 10: burst (fast slow) 245 - 255 Shutter open Dimmer 1 000-255 0 - 100% Red 1 000-255 0 - 100% Green 1 000-255 0 - 100%...
  • Page 50 User Manual 080-084 S-Curve Dimmer Curve (hold 1,5s) 085-089 No function 090-094 LED (Fast) Dimmer Response (hold 1,5s) 095-099 Medium Dimmer Response (hold 1,5s) Halogen(Slow) Dimmer Response 100-104 (hold 1,5s) 105-109 No function Redshift On (hold 1,5s / affects only bet- 110-114 ween 2700-3500K ) 115-119...
  • Page 51 User Manual 38CH STANDARD RGB (Calibrated) Function Value Setting Remark Default Master Dimmer 000-255 0 - 100% Master Dimmer Fine 000-255 0 - 100% 000 - 019 Shutter close 020 - 024 Shutter open 025 - 064 Strobe 1 (fast slow) 065 - 069 Shutter open...
  • Page 52 User Manual Green Fine 2 000-255 0 - 100% Blue 2 000-255 0 - 100% Blue Fine 2 000-255 0 - 100% Dimmer 3 000-255 0 - 100% Dimmer 3 Fine 000-255 0 - 100% Red 3 000-255 0 - 100% Red Fine 3 000-255 0 - 100%...
  • Page 53 User Manual 080-084 S-Curve Dimmer Curve (hold 1,5s) 085-089 No function 090-094 LED (Fast) Dimmer Response (hold 1,5s) 095-099 Medium Dimmer Response (hold 1,5s) Halogen (Slow) Dimmer 100-104 Response (hold 1,5s) 105-109 No function Redshift On (hold 1,5s / affects only bet- 110-114 ween 2700-3500K ) 115-119...
  • Page 54 User Manual 40CH EXTENDED RGB (Calibrated) Function Value Setting Remark Default Master Dimmer 000-255 0 - 100% 000 - 019 Shutter close 020 - 024 Shutter open Shutter 025 - 064 Strobe 1 (fast slow) 065 - 069 Shutter open 070 - 084 Strobe 2: opening pulse (fast slow)
  • Page 55 User Manual Color Macro 1 (override RGB 1/ Please see ROXX color macro chart CTC 1) 000 - 005 no function 006-105 0,1s - 10s (0,1s steps) Color Macro Cross- fade 1 (Transition 106-214 11s - 119s (1s steps) Time between Color...
  • Page 56 User Manual Color Macro 3 (override RGB 3/ Please see ROXX color macro chart CTC 3) 000 - 005 no function 006-105 0,1s - 10s (0,1s steps) Color Macro Cross- fade 3 (Transition 106-214 11s - 119s (1s steps) Time between Color...
  • Page 57 User Manual No Function - Current Preset from Menu 000-51 Settings 052-101 Linear Dimmer Curve Dimmer Curve 102-152 Exponential Dimmer Curve 153-203 Logarithmic Dimmer Curve 204-255 S-Curve Dimmer Curve No Function - Current Preset from Menu 000-063 Settings 064-127 LED / fast Dimmer Response 128-191 Medium...
  • Page 58 User Manual 200-204 Invert Mapping Off (hold 3s) 205-209 Invert Mapping CW (hold 3s) 210-214 Invert Mapping CCW (hold 3s) 215-219 No function Device Settings 220-224 LED Mode - Illumination (hold 1,5s) (please see remark 225-229 LED Mode - Boost (hold 1,5s) 230-234 No function 235-239...
  • Page 59 (affects CTC 1 and 128-128 Neutral RGB 1) 129-255 Neutral -> Green Color Macro 1 (override RGB 1/ Please see ROXX color macro chart CTC 1) 000 - 005 no function 006-105 0,1s - 10s (0,1s steps) Color Macro Cross- fade 1 (Transition...
  • Page 60 User Manual Color Macro 2 (override RGB 2 / Please see ROXX color macro chart CTC 2) 000 - 005 no function 006-105 0,1s - 10s (0,1s steps) Color Macro Cross- fade 2 (Transition 106-214 11s - 119s (1s steps)
  • Page 61 (affects CTC 4 and 128-128 Neutral RGB 4) 129-255 Neutral -> Green Color Macro 4 (override RGB 4 / Please see ROXX color macro chart CTC 4) Color Macro Cross- fade 4 (Transition 000 - 005 no function Time between Color Macros 4)
  • Page 62 User Manual No Function - Current Preset from Menu 000-84 Settings Redshift affects only Redshift between CCT 2700- 085-170 Redshift Off 3500K. 171-255 Redshift On 000-029 No function 030-034 Display Backlight On (hold 3s) 035-039 Display Backlight Off (hold 3s) 040-044 No function 045-049...
  • Page 63 User Manual 20CH DIRECT (RAW) Function Value Setting Remark Default Red 1 000-255 0 - 100% Green 1 000-255 0 - 100% Blue 1 000-255 0 - 100% Amber 1 000-255 0 - 100% White 1 000-255 0 - 100% Red 2 000-255 0 - 100%...
  • Page 64 Magenta -> Neutral (affects CTC and 128-128 Neutral RGBAW) 129-255 Neutral -> Green Color Macro (override RGBAW/ Please see ROXX color macro chart CTC) 000 - 005 no function 006-105 0,1s - 10s (0,1s steps) Color Macro Cross- fade (Transition 106-214...
  • Page 65 User Manual 075-079 Logarithmic Dimmer Curve (hold 1,5s) 080-084 S-Curve Dimmer Curve (hold 1,5s) 085-089 No function 090-094 LED (Fast) Dimmer Response (hold 1,5s) Medium Dimmer Response 095-099 (hold 1,5s) Halogen (Slow) Dimmer Response 100-104 (hold 1,5s) 105-109 No function Redshift On (hold 1,5s / affects only bet- 110-114 ween 2700-3500K )
  • Page 66 User Manual 29CH DIRECT (RAW) Function Value Setting Remark Default Master Dimmer 000-255 0 - 100% 000 - 019 Shutter close 020 - 024 Shutter open 025 - 064 Strobe 1 (fast slow) 065 - 069 Shutter open 070 - 084 Strobe 2: opening pulse (fast slow) 085 - 089...
  • Page 67 User Manual Amber 3 000-255 0 - 100% White 3 000-255 0 - 100% Dimmer 4 000-255 0 - 100% Red 4 000-255 0 - 100% Green 4 000-255 0 - 100% Blue 4 000-255 0 - 100% Amber 4 000-255 0 - 100% White 4...
  • Page 68 User Manual 115-119 Redshift Off (hold 1,5s) 120-124 No function 125-129 RAW (hold 3s) 130-134 User Calibration (hold 3s) 135-139 No function 140-144 LED Frequency 800Hz (hold 3s) 145-149 LED Frequency 1200Hz (hold 3s) 150-154 LED Frequency 2000Hz (hold 3s) 155-159 LED Frequency 3600Hz (hold 3s) 160-164...
  • Page 69 User Manual 48CH DIRECT (RAW) Function Value Setting Remark Default Master Dimmer 000-255 0 - 100% 000 - 019 Shutter close Shutter 020 - 024 Shutter open 025 - 064 Strobe 1 (fast slow) 065 - 069 Shutter open 070 - 084 Strobe 2: opening pulse (fast slow) 085 - 089...
  • Page 70 (affects CTC 1 and 128-128 Neutral RGB 1) 129-255 Neutral -> Green Color Macro 1 (override RGB 1/ Please see ROXX color macro chart CTC 1) 000 - 005 no function 006-105 0,1s - 10s (0,1s steps) Color Macro Cross- fade 1 (Transition...
  • Page 71 (affects CTC 3 and 128-128 Neutral RGB 3) 129-255 Neutral -> Green Color Macro 3 (override RGB 3/ Please see ROXX color macro chart CTC 3) 000 - 005 no function 006-105 0,1s - 10s (0,1s steps) Color Macro Cross- fade 3 (Transition...
  • Page 72 User Manual 000-15 No Function 016-039 Effect 1 (slow to fast) 040-063 Effect 2 (slow to fast) Effect override 064-87 Effect 3 (slow to fast) RGBAW 1-4 / CTC 88-111 Effect 4 (slow to fast) 1-4, Color Macro 1-4 112-135 Effect 5 (slow to fast) 136-159 Effect 6 (slow to fast)
  • Page 73 User Manual 155-159 LED Frequency 3600Hz (hold 3s) 160-164 LED Frequency 12kHz (hold 3s) 165-169 LED Frequency 25kHz (hold 3s) 170-174 No function 175-179 Fan Auto (hold 3s) 180-184 Fan Silent (hold 3s) 185-189 Fan Off (hold 3s) 190-194 Fan High Power (hold 3s) 195-199 No function Device Settings...
  • Page 74 User Manual 73CH DIRECT (RAW) Function Value Setting Remark Default Master Dimmer 000-255 0 - 100% Master Dimmer Fine 000-255 0 - 100% 000 - 019 Shutter close 020 - 024 Shutter open 025 - 064 Strobe 1 (fast slow) 065 - 069 Shutter open 070 - 084...
  • Page 75 Magenta -> Neutral (affects CTC 1 and 128-128 Neutral RGB 1) 129-255 Neutral -> Green Color Macro 1 please use color macros from ROXX color (override RGB 1/ macro chart CTC 1) 000 - 005 no function Color Macro Cross- 006-105...
  • Page 76 (affects CTC 3 and 128-128 Neutral RGB 3) 129-255 Neutral -> Green Color Macro 3 (override RGB 3/ Please see ROXX color macro chart CTC 3) 000 - 005 no function 006-105 0,1s - 10s (0,1s steps) Color Macro Cross- fade 3 (Transition...
  • Page 77 128-128 Neutral RGB 4) 129-255 Neutral -> Green Color Macro 4 (override RGB 4 / Please see ROXX color macro chart CTC 4) 000 - 005 no function 006-105 0,1s - 10s (0,1s steps) Color Macro Cross- fade 4 (Transition...
  • Page 78 User Manual No Function - Current Preset from Menu 000-063 Settings 064-127 LED / fast Dimmer Response 128-191 Medium 192-255 Halogen / slow No Function - Current Preset from Menu 000-84 Settings Redshift affects only Redshift between CCT 2700- 085-170 Redshift Off 3500K.
  • Page 79 User User DMX CHART DMX CHART Manual Manual Color Macro Chart for DMX Gels - Color Macros for DMX Gels - Color Macros for DMX DMX value Gel Name Color Number 093-095 Magenta LEE 113 000-005 no function 096-098 Mauve LEE 126 006-008 100% Red LED...
  • Page 80 User User Manual Manual Color Macro Chart for Stand Alone Gels - Color Macros for Standalone Mode Gels - Color Macros for Standalone Mode Position Gel Name Color Number Position Gel Name Color Number 100% Red LED Lavender LEE 058 Fire LEE 019 Magenta...
  • Page 81 User User Manual Manual CTC channel DMX / Color temperature 10.000 9.500 9.000 8.500 8.000 7.500 7.000 6.500 6.000 5.500 5.000 4.500 4.000 3.500 3.000 2.500 DMX (step) 2.000...
  • Page 82 User User Manual Manual CTC-Chart Color Color Color Color Color Color Temp Temp Temp Temp Temp Temp (Step) (Step) (Step) (Step) (Step) (Step) (°K) (°K) (°K) (°K) (°K) (°K) 5600 4525 2774 3649 5400 6276 5600 4545 2794 3670 5421 6296 5600 2814...
  • Page 83 * Note: During RDM identifying process CLUSTER B4 FC flashes white to blue color alternately. RDM functions For easy identifying ROXX CLUSTER B4 FC during RDM process the unit will jump from white color to blue color every second. Function...
  • Page 84 User User Manual Manual 0x8026 User Calibration- Green 2 0x8027 User Calibration- Blue 2 0x8028 User Calibration- Amber 2 0x8029 User Calibration- White 2 0x802A User Calibration- Red 3 0x802B User Calibration- Green 3 0x802C User Calibration- Blue 3 0x802D User Calibration- Amber 3 0x802E User Calibration- White 3...
  • Page 85 User Manual Sensors RDM enables various readouts for remote device monitoring. See the table below for sensors and sensor types. Please note: The RDM controller communicates with the fixtures to show only the available sensors for this fixture. The table is subject to change without notice. Name Temperature xx°C / xxx°F...
  • Page 86 Hansestr. 91 51149 Köln Email: info@roxxlight.com or the ROXX authorized reseller in your country, from where you purchased your product. Correct Disposal of this product This is for the European Union and European countries with electrical waste collection systems. When this label is shown on the product or brochure it means that the item cannot be disposed with household waste.
  • Page 87 User User Manual Manual CE Compliance The equipment marketed by ROXX GmbH complies (where applicable) with the essential requirements and other specifications of the following Directives: • 2014/30/EU (EMC) • 2014/35/EU (LVD) • 2011/65/EU (RoHS) The complete EU- and UK-Declaration of Conformity can be found at www.roxxlight.com/support, or you can also request it at info@roxxlight.com...

Table of Contents